3. CONNECTION TO AZBIL CONTROL EQUIPMENT
3.5 Control Equipment Side Setting
3 - 51
1
P
R
EP
ARA
T
OR
Y
P
R
OCEDURES
FOR
MONIT
O
R
ING
2
C
O
NNECTION T
O
IAI
ROBO
T
CO
N
T
RO
L
L
E
R
3
CON
N
EC
TI
O
N
T
O
AZBIL
C
O
N
T
ROL
EQU
IP
M
EN
T
4
CONNECTION T
O
OMRON PLC
5
CONNECTI
O
N T
O
OMRO
N TEMPERA
TURE
CONTROL
LE
R
6
CONNECTION T
O
KE
YENCE PL
C
7
CONNE
C
T
ION T
O
KO
YO
EI
PLC
8
CONN
E
CT
ION T
O
JT
EK
T PL
C
3.5.11 Connecting to MPC
Communication settings
Make the communication settings by operating the key
of the control equipment.
*1
Adjust the settings with GOT settings.
*2
Do not set to "0".
*3
Select the station address without overlapping with that of
other units.
3.5.12 Connecting to PBC201-VN2
Communication settings
Make the communication settings by operating the key
of the control equipment.
*1
Adjust the settings with GOT settings.
*2
Do not set to "0".
*3
Select the station address without overlapping with that of
other units.
3.5.13 Connecting to MVF
Communication settings
Make the communication settings by operating the
switch of the control equipment.
*1
Adjust the settings with GOT settings.
*2
Do not set to "0".
*3
Select the station address without overlapping with that of
other units.
Settings by switch
(1) Transmission speed settings
Set the communication condition switch.
(2) Communication condition selection
Set the communication condition switch.
(3) Station address setting
Set the station address switch.
Item
Set value
Transmission speed
*1
9600bps, 19200bps, 38400bps
Communication condition
selection
*1
0: 8-bit data length, Even parity, Stop bit 1
1: 8-bit data length, Non parity, Stop bit 2
Station address
*2*3
0 to 127
Item
Set value
Communication protocol
CPL
Transmission speed
*1
9600bps, 19200bps, 38400bps, 115200bps
Communication condition
selection
*1
(Fixed 8-bit data length)
0:Even parity, Stop bit 1
1:Odd parity, Stop bit 1
2:Non parity, Stop bit 2
Station address
*2*3
0 to 126
Item
Set value
Transmission speed
*1
9600bps, 19200bps
Communication condition
selection
*1
8-bit data length, Even parity, Stop bit 1
8-bit data length, Non parity, Stop bit 2
Station address
*2*3
0 to F
Transmission
speed (bps)
Switch No.
1
2
3
9600
ON
ON
OFF
19200
ON
OFF
OFF
Communication condition
Switch No.
4
8-bit data length, Even parity, Stop bit 1
OFF
8-bit data length, Non parity, Stop bit 2
ON
Communication condition
switch
Display section
Station No. setting switch
Station No. setting switch
Summary of Contents for GOT 1000 Series
Page 2: ......
Page 76: ...1 46 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring ...
Page 78: ......
Page 114: ...2 36 2 CONNECTION TO IAI ROBOT CONTROLLER 2 7 Precautions ...
Page 232: ...5 18 5 CONNECTION TO OMRON TEMPERATURE CONTROLLER 5 7 Precautions ...
Page 254: ...6 22 6 CONNECTION TO KEYENCE PLC 6 4 Device Range that Can Be Set ...
Page 404: ...14 14 14 CONNECTION TO PANASONIC SERVO AMPLIFIER 14 7 Precautions ...
Page 432: ...REVISIONS 3 ...
Page 435: ......