background image

AeGIS 9000 Series

Installation and Programming Manual

PACH AND COMPANY

941 Calle Negocio

Phone: 1-888-678-7224

www.pach-co

.

com 

San Clemente, CA 92673     Fax: 949-498-6879

REV. 7.0

Summary of Contents for AeGIS 9100CR200

Page 1: ...AeGIS 9000 Series Installation and Programming Manual PACH AND COMPANY 941 Calle Negocio Phone 1 888 678 7224 www pach co com San Clemente CA 92673 Fax 949 498 6879 REV 7 0...

Page 2: ......

Page 3: ...Schedule 16 16 Reinitialize Time Zones Schedules 17 17 Reinitialize Auto Unlock Schedules 18 18 Reinitialize Holiday Schedules 18 19 Reinitialize Events Recording 18 20 New Tenant Code 19 21 Modify Te...

Page 4: ...s Code 32 How to to Use the Alarm Telephone Number 32 Relay 2 Modes 32 How the Door Sensor or Shock Sensor Operates 33 How to Adjust the Speaker and Microphone Volume 35 How to Adjust the LCD Display...

Page 5: ...ormation herein implied Pach and Company does not assume any liability for any damages which may arise in installation or use of the AeGIS 9000 Series Pach and Company does not assume liability for an...

Page 6: ...nants MUST have a telephone to allow remote visitor access The system parameters and tenants data will be entered via the keypad and the LCD provides easy display EEPROM technology is used for AeGIS 9...

Page 7: ...Power Input 5 0 VDC Regulated Power by the AeGIS 9000 Series 5VDC regulated or 6 0 24 VDC Unregualted not supplied Transmit Frequency 318 Mhz Bandwith 300 Khz minimum Read Range 5 500 feet Accessories...

Page 8: ...he warranty All implied warranties including warranties for marketability as well as implied warranties for suitability are valid only until the warranty expires or is voided whichever comes first Thi...

Page 9: ...s the right to repair the product or replace a warranted product with a like product of equal value in the event original product cannot be repaired 6 Distributors and or Dealer Installer must first o...

Page 10: ...pair center 9 Pach and Company warranty does not guarantee any product to be free of operation error or service interruption in any way during the course of daily product operation 10 Pach and Company...

Page 11: ...butor and or Dealer Installer are responsible for all shipping charges incl freight and insurance fees for products shipped to Pach and Company repair center 9 Pach and Company warranty does not guara...

Page 12: ...irements as specified in this chapter Figure 2 1 Wiring Block Diagram Pach and Company Chapter 2 Page 4 AeGIS 9000 Series INSTALLATION 2 3 4 5 6 7 1 8 RED BLACK WHITE GREEN 9 INPUT FOR 26 BIT READER R...

Page 13: ...f ASP1 Surge Protector is used If a PBX line is used connect the AeGIS to the analog PBX s extension to dial the extensions within the PBX Do not connect to a PBX s Digital Port NOTE The AeGIS 9000 Se...

Page 14: ...customer supply The life of the battery is approximately 8 hours in idle mode Use two conductors 18 gauge shielded stranded wires WARNING The connection is polarity sensitive Connect the battery term...

Page 15: ...32 DB9 Port The port is used for local programming via AeGIS 9000 Series Management Software See the wiring diagram below for RS 232 connector wiring diagram Figure 2 4 RS 232 CONNECTOR 11 Pach and Co...

Page 16: ...ode 3 2 RS 232 AND REMOTE PROGRAMMING VIA THE PACH AND COMPANY MANAGEMENT SOFTWARE See the enclosed CD for Manual You may install up to eight systems on the same phone line but if Pach and Company Man...

Page 17: ...de to program different field from the table or press to exit the programming mode and the display shows Step 1 Log on to programming mode see section 3 1 The display shows Step 2 Enter Function code...

Page 18: ...Step 2 Enter Function code 03 then press the display shows Step 3 Enter the Lock Out Count value 1 9 then press the display shows Step 4 Select another Function Code to program different field from th...

Page 19: ...de see section 3 1 The display shows Step 2 Enter Function Code 07 then press and the display shows Step 3 Enter 1 to ENABLE and 0 to DISABLE then press the display shows Step 4 Select another Functio...

Page 20: ...Step 1 Log on to programming mode see section 3 1 The display shows Step 2 Enter Function Code 11 then press and the display shows 09 ALARM TELEPHONE NUMBER To alert the manager by calling the phone...

Page 21: ...er you have entered on each segment then the display shows Step 5 Enter 16 characters on the third segment by rewriting the existing message or pressing to clear the segment and reenter the message pr...

Page 22: ...military format then press and enter the MINUTE then press the display shows Step 4 Enter 1 for DAYLIGHT SAVING ZONE or 0 for NON DAYLIGHT SAVING ZONE DO NOT PRESS the display shows Your display may n...

Page 23: ...IF 1 is entered to ADD the display shows proceed to step 5 IF 0 is entered to DELETE the display shows proceed to step 7 Step 5 Enter the START TIME HOUR military time format then press and enter the...

Page 24: ...s and return to step 2 or 0 for NO then press and the display shows Step 7 Select another Function Code to program different field from the table or press to exit the programming mode Step 1 Log on to...

Page 25: ...Enter 1 for YES then press and return to step 2 or 0 for NO then press and the display shows Step 10 Select another Function Code to program different field from the table or press to exit the program...

Page 26: ...n Code 18 then press and the display shows Step 3 Press 1 for YES or 0 for NO then press the display show Step 4 Select another Function Code to program different field from the table or press to exit...

Page 27: ...ring each character and press after entering the last character see figure 3 1 for keypad correlation the display shows Step 5 Enter a telephone number up to 11 digit then press enter the display show...

Page 28: ...shows if tenant code exists proceed to step 5 OR if tenant code does not exist then the display shows proceed to step 5 Step 5 Select another Function Code to program different field from the table o...

Page 29: ...amming mode Step 1 Log on to programming mode see section 3 1 The display shows Step 2 Enter Function Code 24 then press and the display shows Step 3 Enter 0 KEYPAD ACCESS CODE or 1 CARD ACCESS KEYPAD...

Page 30: ...ss the display shows Step 5 Select another Function Code to program different field from the table or press to exit the programming mode Step 1 Log on to programming mode see section 3 1 The display s...

Page 31: ...stem then press the display shows if door 2 is set for mode 1 door control If door 2 is set other than mode 1 proceed to step 6 Step 5 Enter 1 Relay 1 Door 1 2 Relay 2 Door 2 3 Both then press the dis...

Page 32: ...Reader installed on the system then press the display shows if door 2 is set for mode 1 door control If door 2 is set other than mode 1 proceed to step 6 Step 5 Enter 1 Relay 1 Door 1 2 Relay 2 Door 2...

Page 33: ...is valid or Press to CANCEL and proceed to step 5 OR if the keypad access code is invalid THEN display shows Step 5 Select another Function Code to program different field from the table or press to e...

Page 34: ...3 1 The display shows Step 2 Enter Function Code 40 then press and the display shows Step 3 Enter 0 NO or 1 YES then press the display shows Step 4 Select another Function Code to program different f...

Page 35: ...00 Series PROGRAMMING PBX Area No _ _ _ SELECT PROGRAM ENTER _ _ PRESS SELECT PROGRAM ENTER _ _ PRESS Open Door1No 0 9 ENTER _ PRESS If relay 2 door 2 is set for Mode 1 door control the display shows...

Page 36: ...section 3 1 The display shows Step 2 Enter Function Code 50 then press and the display shows Step 3 Enter 1 TO CLEAR or 0 TO CANCEL then press the display shows Step 4 Wait for a few minutes the more...

Page 37: ...de associated with the name Step 4 Press 3 to proceed to next tenant name and return to step 3 or proceed to step 5 or press and the display shows Step 5 Select another Function Code to program differ...

Page 38: ...1 or 8 default setting to unlock relay 2 door 2 2 A DIRECT CALL You must know the tenant directory number to use a direct call The tenant directory number can be associated with apartment number suite...

Page 39: ...setting to unlock relay 1 door 1 or 8 default setting to unlock relay 2 door 2 Step 1 Press then the screen stops scrolling if the screen is still scrolling repeat this step Step 2 Press a valid keypa...

Page 40: ...programmed A phone number on Function Code 29 The system displays shows If invalid keypad access code card access or keypad access code card access are used The system will call the phone number prog...

Page 41: ...t setting on his or her phone to turn ON the camera and monitor the visitors at the system The number can be changed see Function Code 43 Step 4 When finished press 7 default setting to turn OFF the c...

Page 42: ...f Door 1 is still opened after the open interval set on Function Code 02 on relay 1 has expired Or door 1 is forced open Relay 2 will be activated and the display shows You may connect an emergency li...

Page 43: ...is in dial tone mode You cannot program the tenant s directory more than the system capacity An accurate tenant s record is essential You must delete any unused tenant s directory to free the system s...

Page 44: ...lip connector on the speaker and microphone connector must be facing inside the board Check the brown and black wires make sure they are soldered into the microphone Turn the system s power OFF and di...

Page 45: ...ect the phone line from the AeGIS system and connect a standard phone into the phone line and try to place a call Check the phone number on the system programming Check the phone line and make sure th...

Page 46: ...ly Open strike is used the meter will read as an open circuit or RC1 and NC1 or RC2 and NC2 if Normally Close strike is used your meter will read about 0 value Place a call from the system to one of t...

Page 47: ...devices you can connect to your telephone line your tele phone company will provide you upon request In the unlikely event your AeGIS system develops a problem IMMEDIATELY DISCONNECT IT FROM YOUR TELE...

Page 48: ...AeGIS 9000 Series Dial the AeGIS phone number you hear ONE SHORT BEEP if you are connected then press to communicate with the visitor and press 9 or to unlock the door This feature is not applicable...

Page 49: ......

Reviews: