GOT-F900 SERIES (CONNECTION)
Connection of Machine Controller CP9200SH (PLC Manufactured by Yaskawa Electric) 17
17-2
17.2
System Configuration
The MP900/CP9200SH machine controller can be directly connected to the GOT via RS-422 or RS-
232C. This section explains the cables and options required in such a system.
Connectable Model and Connector Shape
The table below shows applicable models and their connector shape.
17.2.1
Configuration for CPU Direct Connection (RS-422)
Connect the MP900/CP9200SH machine controller to the COM port of the MEMOBUS unit and the RS-
422 communication port of the GOT.
The GOT-F900 and the machine controller can be connected on the 1:1 basis.
1) F930GOT/F930GOT-K/F940GOT/F940WGOT
- Applicable machine controller product in the column a) is a MEMOBUS unit equipped with built-in RS-422
interface.
Machine controller
GOT
Remarks
Model
Unit
Port
Connector shape
CP9200SH
CP-217IF
CN1
RS-232C
9-pin D-Sub, male
CN2
RS-232C
25-pin D-Sub, male
CN3
RS-422
8-pin connector, male
MP920
CPU equipped
with built-in ports
PORT1
RS-232C
9-pin D-Sub, male
PORT2
RS-232C
9-pin D-Sub, male
CP-217IF
CN1
RS-232C
9-pin D-Sub, male
CN2
RS-232C
9-pin D-Sub, male
CN3
RS-422
8-pin connector, male
MP930
CPU equipped
with built-in ports
PORT1
RS-232C
9-pin D-Sub, male
PORT2
RS-232C
9-pin D-Sub, male
a) Machine controller
b) RS-422 cable
Remarks
CP-217IF
Dedicated 8-pin
connector
Prepared by the user
MEMOBUS unit
b) RS-422 cable
F940GOT
F943GOT
F930GOT
GOT-F900
a) Machine controller
MEMOBUS unit
CP9200SH,MP920
CP-217IF
Summary of Contents for F920GOT-BBD-K-E
Page 4: ...GOT F900 SERIES CONNECTION ii ...
Page 6: ...GOT F900 SERIES CONNECTION iv ...
Page 38: ...GOT F900 SERIES CONNECTION Outline 2 2 10 MEMO ...
Page 70: ...GOT F900 SERIES CONNECTION Specifications 3 3 32 MEMO ...
Page 230: ...GOT F900 SERIES CONNECTION Connection of MELSEC F FX Series PLC 8 8 26 MEMO ...
Page 260: ...GOT F900 SERIES CONNECTION Connection of MELSEC A Series PLC 9 9 30 MEMO ...
Page 290: ...GOT F900 SERIES CONNECTION Connection of MELSEC QnA Series PLC 10 10 30 MEMO ...
Page 322: ...GOT F900 SERIES CONNECTION Connection of MELSEC Q Series PLC 11 11 32 MEMO ...
Page 376: ...GOT F900 SERIES CONNECTION Connection of FREQROL S500 E500 A500 Inverter 13 13 38 MEMO ...
Page 412: ...GOT F900 SERIES CONNECTION Connection of Microcomputer 14 14 36 MEMO ...
Page 554: ...GOT F900 SERIES CONNECTION Connection of Printer 21 21 8 MEMO ...
Page 590: ...GOT F900 SERIES CONNECTION Appendix 23 23 24 MEMO ...
Page 591: ......