GOT-F900 SERIES (CONNECTION)
Connection of Two or More GOT Units 7
7-2
7.2
Connection Configuration for Two or More GOT Units
When connecting two or more GOT-F900 units, for the first GOT-F900 unit, refer to the connection
method for each equipment (FX/A/QnA/Q Series PLC and microcomputer) in this manual. This section
explains cables required to connect among the second and later GOT units.
Handling of the Handy GOT
Only one Handy GOT unit can be connected at the end. (Up to four GOT units can be connected in total
including one Handy GOT unit).
7.2.1
Configuration When First GOT Unit is Connected through RS-422
This section explains the configuration when the first GOT-F900 is already connected through RS-422.
- The configuration of the first unit is as shown in the table below. For the details, however, refer to
section explaining each connected equipment also.
*1 For the length of the Handy GOT cable, refer to chapter 5.
1) F930GOT, F930GOT-K, F940GOT and F940WGOT
- Among RS-422 cables in the FX-50DU-CABL and the FX-50DU-CAB0L cannot be used in the F930GOT/
F930GOT-K.
a) FX/A/QnA/Q Series PLC, microcomputer
b) RS-422 cable
c) RS-232C cable d) RS-422 cable
FX/FX
2C
(CPU direct connection)
(25-pin D-Sub)
FX-40DU-CAB
FX-40DU-CAB-
""
M
FX-50DU-CABL
FX-232CAB-1
Prepared by user
(cross cable)
A/QnA (CPU direct connection)
(25-pin D-Sub)
FX
0
/FX
0S
/FX
1S
/F
X0N
/
FX
1N
/FX
2N
/FX
2NC
(CPU direct connection)
(8-pin MINI DIN)
FX-50DU-CAB0
FX-50DU-CAB0/EN
FX-50DU-CAB0-
""
M
FX-50DU-CAB0L
FX-232CAB-1
Prepared by user
(cross cable)
FX
1S
+ FX
1N
-422-BD
FX
1N
+ FX
1N
-422-BD
FX
2N
+ FX
2N
-422-BD
(8-pin MINI DIN)
QnA computer link connection
Prepared by user
FX-232CAB-1
Prepared by user
(cross cable)
Q computer link connection
Prepared by user
FX-232CAB-1
Prepared by user
(cross cable)
Microcomputer connection
Prepared by user
FX-232CAB-1
Prepared by user
(cross cable)
a) FX/A/QnA/Q
Series PLC
Microcomputer
b)RS-422
c)RS-232C
1
2
d)RS-422
3
c)RS-232C
F930GOT(-K)
F940(W)GOT
F930GOT(-K)
F940(W)GOT
F930GOT(-K)
F940(W)GOT
F943 Handy GOT
F930GOT(-K)
F940(W)GOT
15m(49' 3")
*1
30m
15m
30m
4
b)RS-422
c)RS-232C
1
2
d)RS-422
F940 Handy GOT
3
Q computer link
(98' 5")
(49' 3")
(98' 5")
(6m(19' 8") or less when
using Handy GOT)
11.5m
*1
15m
30m
(98' 5")
(49' 3")
(37' 9")
Summary of Contents for F920GOT-BBD-K-E
Page 4: ...GOT F900 SERIES CONNECTION ii ...
Page 6: ...GOT F900 SERIES CONNECTION iv ...
Page 38: ...GOT F900 SERIES CONNECTION Outline 2 2 10 MEMO ...
Page 70: ...GOT F900 SERIES CONNECTION Specifications 3 3 32 MEMO ...
Page 230: ...GOT F900 SERIES CONNECTION Connection of MELSEC F FX Series PLC 8 8 26 MEMO ...
Page 260: ...GOT F900 SERIES CONNECTION Connection of MELSEC A Series PLC 9 9 30 MEMO ...
Page 290: ...GOT F900 SERIES CONNECTION Connection of MELSEC QnA Series PLC 10 10 30 MEMO ...
Page 322: ...GOT F900 SERIES CONNECTION Connection of MELSEC Q Series PLC 11 11 32 MEMO ...
Page 376: ...GOT F900 SERIES CONNECTION Connection of FREQROL S500 E500 A500 Inverter 13 13 38 MEMO ...
Page 412: ...GOT F900 SERIES CONNECTION Connection of Microcomputer 14 14 36 MEMO ...
Page 554: ...GOT F900 SERIES CONNECTION Connection of Printer 21 21 8 MEMO ...
Page 590: ...GOT F900 SERIES CONNECTION Appendix 23 23 24 MEMO ...
Page 591: ......