GOT-F900 SERIES (CONNECTION)
Connection of SIMATIC S7-200/300/400 Series PLC (Manufactured by Siemens AG) 20
20-12
20.7
Setting of Connected Equipment for GOT
The SIMATIC S7-200/300/400 Series PLC connection parameters can be set using the GOT-F900
Series and the screen creation software (GT Designer 2, GT Designer or DU/WIN).
1) GOT-F900 Series
When the main menu screen change operation is disabled.
When the main menu screen change operation is enabled.
- When the screen data is transferred to the GOT-F900, the old data including the PLC type, connection type,
and station number are overwritten.
Operation
Display (screen name)
a)While pressing and holding the upper left corner of the screen,
turn on the power. Keep holding the upper left corner for about
25 seconds more.
Then, press "END" at the upper right corner.
The "LANGUAGE" screen appears.
The "SET-UP MODE" screen appears.
b)Press "PLC TYPE".
c) Set the following.
PLC TYPE: SIEMENS S7-200
SIEMENS S7-300
CONNECTION:CPU PORT (RS-232C)
(S7-200)
DST STATION # : 1 to 31
GOT STATION # : 0 to 31
(S7-300)
DST STATION # (STATION #): 02 to 31
("00" and "01" are treated as "02".)
GOT STATION # (
−
)
:
−
The "PLC TYPE" screen appears.
Operation
Display (screen name)
a)Press the upper left corner of the screen. (The position to be
pressed can be changed in the GOT and the screen creation
software.)
The "SELECT MODE" screen appears.
b)Press "OTHER MODE" on the menu.
The "OTHER MODE" screen appears.
c) Press "SET-UP MODE" on the menu.
The "SET-UP MODE" screen appears.
d)Press "PLC TYPE".
e)Set the following.
PLC TYPE: SIEMENS S7-200
SIEMENS S7-300
CONNECTION:CPU PORT (RS-232C)
(S7-200)
DST STATION # : 1 to 31
GOT STATION # : 0 to 31
(S7-300)
DST STATION # (STATION #): 02 to 31
("00" and "01" are treated as "02".)
GOT STATION # (
−
)
:
−
The "PLC TYPE" screen appears.
Summary of Contents for F920GOT-BBD-K-E
Page 4: ...GOT F900 SERIES CONNECTION ii ...
Page 6: ...GOT F900 SERIES CONNECTION iv ...
Page 38: ...GOT F900 SERIES CONNECTION Outline 2 2 10 MEMO ...
Page 70: ...GOT F900 SERIES CONNECTION Specifications 3 3 32 MEMO ...
Page 230: ...GOT F900 SERIES CONNECTION Connection of MELSEC F FX Series PLC 8 8 26 MEMO ...
Page 260: ...GOT F900 SERIES CONNECTION Connection of MELSEC A Series PLC 9 9 30 MEMO ...
Page 290: ...GOT F900 SERIES CONNECTION Connection of MELSEC QnA Series PLC 10 10 30 MEMO ...
Page 322: ...GOT F900 SERIES CONNECTION Connection of MELSEC Q Series PLC 11 11 32 MEMO ...
Page 376: ...GOT F900 SERIES CONNECTION Connection of FREQROL S500 E500 A500 Inverter 13 13 38 MEMO ...
Page 412: ...GOT F900 SERIES CONNECTION Connection of Microcomputer 14 14 36 MEMO ...
Page 554: ...GOT F900 SERIES CONNECTION Connection of Printer 21 21 8 MEMO ...
Page 590: ...GOT F900 SERIES CONNECTION Appendix 23 23 24 MEMO ...
Page 591: ......