GOT-F900 SERIES (CONNECTION)
Installation and Wiring of Handy GOT 5
5-35
1
In
tr
o
d
u
c
tio
n
2
Ou
tl
in
e
3
S
p
eci
fic
a
ti
on
s
4
in
st
a
ll
a
ti
o
n
an
d W
iri
ng
o
f
F9
40
G
O
T
5
in
s
ta
llat
io
n
an
d W
ir
in
g
of
Ha
n
d
y
GO
T
6
C
o
nne
c
ti
o
n of
P
e
ri
ph
er
al
Eq
ui
pm
en
t
7
C
o
nn
ect
io
n o
f
T
w
o or
Mor
e
GO
T
U
n
it
s
8
C
o
nn
ec
ti
o
n
of
M
E
LSEC-
F
F
X
Se
ri
e
s
PLC
9
C
o
n
n
e
c
ti
on of
M
E
L
SEC-
A
Se
ri
e
s
PLC
10
C
o
n
n
e
c
ti
on
of
M
E
L
SEC-
Q
n
A
Se
ri
e
s
PLC
3) Lighting of LEDs for confirming operation
A green LED is provided for each of four operation switches SW1 to SW4 and one grip switch so that
pressing of each switch can be confirmed.
Each LED is assigned to a bit device by the screen creation software. When the value of a bit device
is "1", the corresponding switch is lit. When the value is "0", the corresponding switch is
extinguished.
a) Assignment of devices controlling the LEDs
b) Setting in the screen creation software
The head device for the LEDs of the operation switches should be set in the screen creation soft-
ware.
For the details, refer to section 5.14.
c) Program example
The operation switches SW1, SW2, SW3 and SW4 are assigned to X0, X1, X2 and X3 respec-
tively. The grip switch is wired to X4.
The device of "Output Indicator" is set to M100 in the screen creation software.
In a sequence program, inputs X0 to X4 are assigned to M100 to M104 using the OUT instruction.
Device
Name
M100
Operation switch SW1 (green)
←
Set this device using the screen creation software.
The LEDs for the operation switches and grip switch
can be allocated successively.
M101
Operation switch SW2 (green)
M102
Operation switch SW3 (green)
M103
Operation switch SW4 (green)
M104
Grip switch (green)
←
Valid when the OS version is 6.00 or later
X0
M100
X3
M103
. . . . . When the SW1 is pressed, the LED lights in green.
. . . . .
. . . . .When the SW4 is pressed, the LED lights in green.
X4
M104 . . . . . The LED of the grip switch lights in green.
Summary of Contents for F920GOT-BBD-K-E
Page 4: ...GOT F900 SERIES CONNECTION ii ...
Page 6: ...GOT F900 SERIES CONNECTION iv ...
Page 38: ...GOT F900 SERIES CONNECTION Outline 2 2 10 MEMO ...
Page 70: ...GOT F900 SERIES CONNECTION Specifications 3 3 32 MEMO ...
Page 230: ...GOT F900 SERIES CONNECTION Connection of MELSEC F FX Series PLC 8 8 26 MEMO ...
Page 260: ...GOT F900 SERIES CONNECTION Connection of MELSEC A Series PLC 9 9 30 MEMO ...
Page 290: ...GOT F900 SERIES CONNECTION Connection of MELSEC QnA Series PLC 10 10 30 MEMO ...
Page 322: ...GOT F900 SERIES CONNECTION Connection of MELSEC Q Series PLC 11 11 32 MEMO ...
Page 376: ...GOT F900 SERIES CONNECTION Connection of FREQROL S500 E500 A500 Inverter 13 13 38 MEMO ...
Page 412: ...GOT F900 SERIES CONNECTION Connection of Microcomputer 14 14 36 MEMO ...
Page 554: ...GOT F900 SERIES CONNECTION Connection of Printer 21 21 8 MEMO ...
Page 590: ...GOT F900 SERIES CONNECTION Appendix 23 23 24 MEMO ...
Page 591: ......