GOT-F900 SERIES (CONNECTION)
Connection of Peripheral Equipment 6
6-8
6.3.3
Changeover of Connection between PLC and Personal Computer
For connecting a personal computer, the status of the PLC port of the F943 Handy GOT should be
changed over from PLC connection to personal computer connection (screen data transfer) by the
screen operation. The operations of the Handy GOT are explained below.
1) Startup operation
<When the OS version is 6.00 or later>
When the SELECT MODE screen change operation is disabled.
When the main SELECT MODE change operation is enabled.
2) Screen operation
When the "DATA TRANSFER" screen shown below appears, set "PORT" to "EXTERNAL PORT" by
touching the screen.
When changing over the screen to a user screen after having transferred the screen data,
"INTERNAL PORT" is automatically specified and communication with the PLC is enabled.
3) Caution on use
Though "PORT" is displayed also in the F940 Handy GOT, it is invalid because only RS-422
connection is available.
Operation
Display (screen name)
a)While pressing and holding the upper left corner of the screen,
turn on the power. Keep holding the upper left corner for about
25 seconds more.
Then, press "END" at the upper right corner.
The "LANGUAGE" screen appears.
The "SET-UP MODE" screen appears.
b)Press "END" at the upper right corner.
The "SELECT MODE" screen appears.
c) Press "OTHER MODE" on the menu.
The "OTHER MODE" screen appears.
d)Press "DATA TRANSFER" on the menu.
The "DATA TRANSFER" screen appears.
Operation
Display (screen name)
a)Press the upper left corner of the screen. (The position to be
pressed can be changed in the GOT and the screen creation
software.)
The "SELECT MODE" screen appears.
b)Press "OTHER MODE" on the menu.
The "OTHER MODE" screen appears.
c) Press "DATA TRANSFER" on the menu.
The "DATA TRANSFER" screen appears.
PORT
EXTERNL PORT
Specifies the PLC connector.
INTERNAL PORT Specifies the personal computer port (RS-232C) provided on the rear face.
DATA TRANSFER
END
PORT
GOT
↔
PC
WATING
EXTERNL PORT
Summary of Contents for F920GOT-BBD-K-E
Page 4: ...GOT F900 SERIES CONNECTION ii ...
Page 6: ...GOT F900 SERIES CONNECTION iv ...
Page 38: ...GOT F900 SERIES CONNECTION Outline 2 2 10 MEMO ...
Page 70: ...GOT F900 SERIES CONNECTION Specifications 3 3 32 MEMO ...
Page 230: ...GOT F900 SERIES CONNECTION Connection of MELSEC F FX Series PLC 8 8 26 MEMO ...
Page 260: ...GOT F900 SERIES CONNECTION Connection of MELSEC A Series PLC 9 9 30 MEMO ...
Page 290: ...GOT F900 SERIES CONNECTION Connection of MELSEC QnA Series PLC 10 10 30 MEMO ...
Page 322: ...GOT F900 SERIES CONNECTION Connection of MELSEC Q Series PLC 11 11 32 MEMO ...
Page 376: ...GOT F900 SERIES CONNECTION Connection of FREQROL S500 E500 A500 Inverter 13 13 38 MEMO ...
Page 412: ...GOT F900 SERIES CONNECTION Connection of Microcomputer 14 14 36 MEMO ...
Page 554: ...GOT F900 SERIES CONNECTION Connection of Printer 21 21 8 MEMO ...
Page 590: ...GOT F900 SERIES CONNECTION Appendix 23 23 24 MEMO ...
Page 591: ......