GOT-F900 SERIES (CONNECTION)
Installation and Wiring of Handy GOT 5
5-33
1
In
tr
o
d
u
c
tio
n
2
Ou
tl
in
e
3
S
p
eci
fic
a
ti
on
s
4
in
st
a
ll
a
ti
o
n
an
d W
iri
ng
o
f
F9
40
G
O
T
5
in
s
ta
llat
io
n
an
d W
ir
in
g
of
Ha
n
d
y
GO
T
6
C
o
nne
c
ti
o
n of
P
e
ri
ph
er
al
Eq
ui
pm
en
t
7
C
o
nn
ect
io
n o
f
T
w
o or
Mor
e
GO
T
U
n
it
s
8
C
o
nn
ec
ti
o
n
of
M
E
LSEC-
F
F
X
Se
ri
e
s
PLC
9
C
o
n
n
e
c
ti
on of
M
E
L
SEC-
A
Se
ri
e
s
PLC
10
C
o
n
n
e
c
ti
on
of
M
E
L
SEC-
Q
n
A
Se
ri
e
s
PLC
5.8
Wiring for 24V DC Power Supply and Class D Grounding
The power is supplied from the external power supply to the Handy GOT.
The current consumption is 300mA at 24V DC.
Example when the power is supplied from the external power supply
Connect the power cable (untied wires) or connector of the Handy GOT to the 24V DC external power supply.
*1 Caution on class D grounding according to input power supply
a) When the input power supply is equivalent
b) When the input power supply is different
Pin layout
Recommended feature size of terminal (H9GT-HCNB conversion box)
Signal name
External cable
Connector conversion box
F9GT-HCAB-
"
"
"
"
M
F9GT-HCAB1-
"
"
"
"
M
F9GT-RHCAB-
"
"
"
"
M
F9GT-HCNB
24+
24,25
Blue/white, gray/white
36,37
DC24V+
24G
12,13
Purple, orange
18,19
DC24VG
FG
1
Drain wire
1
FG
P L C
2 4
X 4
X 0
X 1
X 2
X 3
T o o p e r a t i o n
s w i t c h e s o f
H a n d y G O T
0 V
S / S
* 1
F G
2 4 +
2 4 G
H a n d y G O T
E x t e r n a l
p o w e r s u p p l y
C l a s s D
g r o u n d i n g
C l a s s D
g r o u n d i n g
P L C
C l a s s D g r o u n d i n g
H a n d y
G O T
F G
E x t e r n a l
p o w e r
s u p p l y
P L C
H a n d y
G O T
1 0 0 V A C
2 0 0 V A C
C l a s s D g r o u n d i n g
E x t e r n a l
p o w e r
s u p p l y
F G
When the input power for the PLC main unit is
equivalent to the input power for the external
power supply (24V DC), grounding may be
performed by connecting the frame ground of
the Handy GOT to the ground terminal (
) of
the PLC.
When the input power supply of the external
power supply is different (PLC: 200V AC,
external power supply: 100V AC), perform
dedicated grounding to each of the PLC and
Handy GOT separately.
Terminal screw
Pressure terminal
Terminal
6.2mm(0.24")
or less
φ
3.2(0.13")
6.2mm(0.24")
or less
φ
3.2(0.13")
Summary of Contents for F920GOT-BBD-K-E
Page 4: ...GOT F900 SERIES CONNECTION ii ...
Page 6: ...GOT F900 SERIES CONNECTION iv ...
Page 38: ...GOT F900 SERIES CONNECTION Outline 2 2 10 MEMO ...
Page 70: ...GOT F900 SERIES CONNECTION Specifications 3 3 32 MEMO ...
Page 230: ...GOT F900 SERIES CONNECTION Connection of MELSEC F FX Series PLC 8 8 26 MEMO ...
Page 260: ...GOT F900 SERIES CONNECTION Connection of MELSEC A Series PLC 9 9 30 MEMO ...
Page 290: ...GOT F900 SERIES CONNECTION Connection of MELSEC QnA Series PLC 10 10 30 MEMO ...
Page 322: ...GOT F900 SERIES CONNECTION Connection of MELSEC Q Series PLC 11 11 32 MEMO ...
Page 376: ...GOT F900 SERIES CONNECTION Connection of FREQROL S500 E500 A500 Inverter 13 13 38 MEMO ...
Page 412: ...GOT F900 SERIES CONNECTION Connection of Microcomputer 14 14 36 MEMO ...
Page 554: ...GOT F900 SERIES CONNECTION Connection of Printer 21 21 8 MEMO ...
Page 590: ...GOT F900 SERIES CONNECTION Appendix 23 23 24 MEMO ...
Page 591: ......