23.1.2
Assigning Device to Control ON/OFF Status of the Backlight
The backlight ON/OFF status can be controlled by setting to ON or OFF the backlight control device set
in the screen creation software by a sequence program.
1) In the case of screen creation software (GT Designer2)
In the sequence program example shown below, the read device is set to "D10".
D10 b1: Backlight control
(When this bit is set to ON, the backlight will turn off after the specified time.)
Read device (system signal 1)
For the details of the system information, refer to the GOT-F900 OPERATION MANUAL (GT
Designer2) or the manual of the screen creation software.
When a data file created using the DU/WIN is used (only in the GOT-F900) or when the data is read
from the GOT-F900, execute the following procedure.
A sequence program example is equivalent to the example shown for the DU/WIN later.
Operating procedure Tool menu
Select "Common"-"System Environment".
Click "System Information" in the tree displayed on the "System
Environment" dialog box, then set "Read Device".
Tree in the project work space
Double-click "Common"-"System Environment".
Click "System Information" in the tree displayed on the "System
Environment" dialog box, then set "Read Device".
b15
b14
b13
b12
b11
b10
b9
b8
b7
b6
b5
b4
b3
b2
b1
b0
Backlight control
Operating procedure Tool menu
Select "Common"-"System Environment".
Click "Interface Device" in the tree displayed on the "System Environment"
dialog box, then set "Bit Device".
Tree in the project work space
Double-click "Common"-"System Environment".
Click "Interface Device" in the tree displayed on the "System Environment"
dialog box, then set "Bit Device".
M11
M8000 (RUN monitor)
MOV
K3M10
D10
ON = Extinguished/OFF = Lit
M21 to M10
→
D10
Summary of Contents for F920GOT-BBD-K-E
Page 4: ...GOT F900 SERIES CONNECTION ii ...
Page 6: ...GOT F900 SERIES CONNECTION iv ...
Page 38: ...GOT F900 SERIES CONNECTION Outline 2 2 10 MEMO ...
Page 70: ...GOT F900 SERIES CONNECTION Specifications 3 3 32 MEMO ...
Page 230: ...GOT F900 SERIES CONNECTION Connection of MELSEC F FX Series PLC 8 8 26 MEMO ...
Page 260: ...GOT F900 SERIES CONNECTION Connection of MELSEC A Series PLC 9 9 30 MEMO ...
Page 290: ...GOT F900 SERIES CONNECTION Connection of MELSEC QnA Series PLC 10 10 30 MEMO ...
Page 322: ...GOT F900 SERIES CONNECTION Connection of MELSEC Q Series PLC 11 11 32 MEMO ...
Page 376: ...GOT F900 SERIES CONNECTION Connection of FREQROL S500 E500 A500 Inverter 13 13 38 MEMO ...
Page 412: ...GOT F900 SERIES CONNECTION Connection of Microcomputer 14 14 36 MEMO ...
Page 554: ...GOT F900 SERIES CONNECTION Connection of Printer 21 21 8 MEMO ...
Page 590: ...GOT F900 SERIES CONNECTION Appendix 23 23 24 MEMO ...
Page 591: ......