GOT-F900 SERIES (CONNECTION)
Connection of FREQROL (S500/E500/A500) Inverter 13
13-11
11
C
o
n
n
e
c
ti
on
of
ME
L
S
E
C
-Q
Se
ri
e
s
PL
C
12
Co
n
n
e
c
ti
o
n
o
f
FX Se
ri
e
s
Po
s
it
io
n
in
g
13
C
o
n
n
e
c
ti
on o
f
FR
EQ
R
O
L
In
ve
rt
er
14
C
onn
ec
ti
o
n
of
Mi
cr
o
c
o
m
-
put
e
r
15
C
o
nn
ec
ti
o
n
of
S
YSM
A
C
C
Se
ri
e
s
PL
C
16
C
o
nne
c
ti
o
n of
F
L
EX-
PC N
Se
ri
e
s
PL
C
17
C
o
nn
ect
io
n o
f
M
a
c
h
in
e
C
on-
troll
e
r
18
C
o
nn
ec
ti
o
n
of
FP
Se
ri
e
s
PL
C
19
C
o
n
n
e
c
ti
on o
f
S
L
C
500
Se
ri
e
s
PLC
20
C
o
n
n
e
c
ti
on
of
SI
M
A
T
IC S7
Se
ri
e
s
PLC
13.4
Cautions on Use of FREQROL Series Inverter
When using the GOT-F900 connected to the FREQROL Series inverter, observe the following cautions
on use.
13.4.1
Device specification
Devices correspond to parameters of the FREQROL Series inverter. Accordingly, the device range
specifications vary depending on the model.
For the details of parameters, refer to section 13.6.
•
Among word devices, only unsigned 16-bit numeric values can be used.
GOT internal data registers (GD) are excluded.
•
In screen changeover, GOT internal data registers (GD) can be specified.
•
Only GOT internal data registers (GD) can be specified for the system information of the GT
Designer. GOT internal bit registers (GB) and GOT internal data registers (GD) only can be specified
for control devices of the DU/WIN.
•
In the status monitoring function, the alarm code (A) device cannot be specified as the operation
device (word SET).
In the control status (S) device, only one operation (bit) device can be specified.
•
Because the time switch cannot use the bit device control status (S), this function is not available.
•
The alarm code (A) device cannot be specified in the following devices.
Recipe function
Write device of operation panel (word SET)
Bar code
Numeric input
ASCII input
Operation device of touch key (word SET)
Device for storing number of histories of alarm history
Device for storing number of occurrences of alarm list
13.4.2
Changeover from the GOT (communication) to the PU operation mode
-
Not available in the S500 Series.
-
Available in the E500 Series.
-
Not available in the A500 Series if the GOT is connected to the communication board FR-A5NR.
13.4.3
When "8888" or "9999" is set to a parameter (Pr) of the inverter
Numbers "8888" and "9999" have special meaning respectively. When specifying such numbers from
the GOT-F900, specify them as follows.
Device names and devices
which can be monitored in
GOT
a)
b)
c)
d)
e)
f)
Unsigned
16-bit
Screen
changeover
System information/
control device
Status
monitor
Time
switch
Others
Control status (S)
−
−
−
%
−
$
GOT internal bit register (GB)
−
−
$
−
−
$
Alarm code (A)
$
−
−
−
−
−
Parameter (Pr)
$
−
−
$
−
$
Program operation (PG)
$
−
−
$
−
$
Special parameter (SP)
$
−
−
$
−
$
GOT internal data register
(GD)
$
$
$
$
−
$
Set value on inverter side
Value to be specified in GOT-F900
8888
65520
9999
65535
Summary of Contents for F920GOT-BBD-K-E
Page 4: ...GOT F900 SERIES CONNECTION ii ...
Page 6: ...GOT F900 SERIES CONNECTION iv ...
Page 38: ...GOT F900 SERIES CONNECTION Outline 2 2 10 MEMO ...
Page 70: ...GOT F900 SERIES CONNECTION Specifications 3 3 32 MEMO ...
Page 230: ...GOT F900 SERIES CONNECTION Connection of MELSEC F FX Series PLC 8 8 26 MEMO ...
Page 260: ...GOT F900 SERIES CONNECTION Connection of MELSEC A Series PLC 9 9 30 MEMO ...
Page 290: ...GOT F900 SERIES CONNECTION Connection of MELSEC QnA Series PLC 10 10 30 MEMO ...
Page 322: ...GOT F900 SERIES CONNECTION Connection of MELSEC Q Series PLC 11 11 32 MEMO ...
Page 376: ...GOT F900 SERIES CONNECTION Connection of FREQROL S500 E500 A500 Inverter 13 13 38 MEMO ...
Page 412: ...GOT F900 SERIES CONNECTION Connection of Microcomputer 14 14 36 MEMO ...
Page 554: ...GOT F900 SERIES CONNECTION Connection of Printer 21 21 8 MEMO ...
Page 590: ...GOT F900 SERIES CONNECTION Appendix 23 23 24 MEMO ...
Page 591: ......