GOT-F900 SERIES (CONNECTION)
Connection of SLC500/MicroLogix Series PLC (Manufactured by Allen-Bradley) 19
19-2
3.
Others
19.1
System Condition
When connecting the SLC500/MicroLogix Series PLC, check the COM port designation, the OS version
of the GOT-F900, and applicable versions of the screen creation software.
Compatibility when connecting SLC500 Series PLC
Compatibility when connecting MicroLogix Series PLC
- The screen creation software (GT Designer) Version SW5-F (5.05F) or later which is applicable to the
MicroLogix Series is required.
Screens cannot be created using a version earlier than SW5-F (5.05F). Prepare an applicable version.
- The screen creation software (DU/WIN) version 2.50 or later which is applicable to the MicroLogix Series is
required.
Screens cannot be created using a version earlier than 2.50. Prepare an applicable version.
*1 Excluding the 5V type F920GOT-K.
Item name
Description
Reference
Cable Diagram
Cable diagrams for SLC500/MicroLogix Series PLC and GOT connection
19.8
Troubleshooting
Description of errors and how to fix them
19.9
GOT-F900
Series
COM port
Connection type
OS version
of GOT-F900
Version of screen creation
software
RS-422
RS-232C
1:1
Two or more
GOT units
GT
Designer2
GT
Designer
DU/WIN
F920GOT-K(5V)
−
−
−
−
−
−
−
−
F920GOT-K(24V)
−
✓
✓
−
1.20
SW1-C
−
−
F930GOT
−
✓
✓
−
2.00
SW1-C
SW1-H
2.30
F930GOT-K
−
✓
✓
−
4.60
SW1-C
SW5-26C
2.70
F940GOT
−
✓
✓
−
2.00
SW1-C
SW1-A
2.30
F940WGOT
−
✓
✓
−
1.00
SW1-C
SW5-F
2.50
F940 Handy GOT
−
−
It cannot be connected. Select the F943 Handy GOT.
F943 Handy GOT
−
✓
✓
−
2.00
SW1-C
SW1-D
2.30
Type
F920GOT-K
F930GOT
F930GOT-K
F940GOT
F940WGOT
Handy GOT
GOT-F900 OS version
1.20
*1
4.00
4.60
6.00
1.00
6.00
Summary of Contents for F920GOT-BBD-K-E
Page 4: ...GOT F900 SERIES CONNECTION ii ...
Page 6: ...GOT F900 SERIES CONNECTION iv ...
Page 38: ...GOT F900 SERIES CONNECTION Outline 2 2 10 MEMO ...
Page 70: ...GOT F900 SERIES CONNECTION Specifications 3 3 32 MEMO ...
Page 230: ...GOT F900 SERIES CONNECTION Connection of MELSEC F FX Series PLC 8 8 26 MEMO ...
Page 260: ...GOT F900 SERIES CONNECTION Connection of MELSEC A Series PLC 9 9 30 MEMO ...
Page 290: ...GOT F900 SERIES CONNECTION Connection of MELSEC QnA Series PLC 10 10 30 MEMO ...
Page 322: ...GOT F900 SERIES CONNECTION Connection of MELSEC Q Series PLC 11 11 32 MEMO ...
Page 376: ...GOT F900 SERIES CONNECTION Connection of FREQROL S500 E500 A500 Inverter 13 13 38 MEMO ...
Page 412: ...GOT F900 SERIES CONNECTION Connection of Microcomputer 14 14 36 MEMO ...
Page 554: ...GOT F900 SERIES CONNECTION Connection of Printer 21 21 8 MEMO ...
Page 590: ...GOT F900 SERIES CONNECTION Appendix 23 23 24 MEMO ...
Page 591: ......