GOT-F900 SERIES (CONNECTION)
Connection of SYSMAC C Series PLC (Manufactured by Omron) 15
15-17
11
C
o
n
n
e
c
ti
on
of
ME
L
S
E
C
-Q
Se
ri
e
s
PL
C
12
Co
n
n
e
c
ti
o
n
o
f
FX Se
ri
e
s
Po
s
it
io
n
in
g
13
C
o
n
n
e
c
ti
on o
f
FR
EQ
R
O
L
In
ve
rt
er
14
C
onn
ec
ti
o
n
of
Mi
cr
o
c
o
m
-
put
e
r
15
C
o
nn
ec
ti
o
n
of
S
YSM
A
C
C
Se
ri
e
s
PL
C
16
C
o
nne
c
ti
o
n of
F
L
EX-
PC N
Se
ri
e
s
PL
C
17
C
o
nn
ect
io
n o
f
M
a
c
h
in
e
C
on-
troll
e
r
18
C
o
nn
ec
ti
o
n
of
FP
Se
ri
e
s
PL
C
19
C
o
n
n
e
c
ti
on o
f
S
L
C
500
Se
ri
e
s
PLC
20
C
o
n
n
e
c
ti
on
of
SI
M
A
T
IC S7
Se
ri
e
s
PLC
15.7
Caution on Use of SYSMAC C Series PLC
When using the GOT-F900 connected to the SYSMAC C Series PLC, observe the following caution on
use.
15.7.1
Modes in the SYSMAC C Series PLC
When the GOT-F900 is connected to the SYSMAC C Series PLC and the current value and the set value
of each device of the SYSMAC C Series PLC are changed, the PLC should be set to the monitor mode.
If the SYSMAC C Series PLC is started up in the running mode, the GOT-F900 sets automatically the
PLC to the monitor mode.
15.7.2
Forced ON/OFF on the device monitor screen of the GOT-F900
The bit device ON/OFF function is provided on the user screen of the GOT-F00 and the forced ON/OFF
function is provided on the device monitor screen in the HPP mode. These functions are also available
when the SYSMAC C Series PLC is connected as the host unit.
Have in mind that these ON/OFF functions offer the following operation in the SYSMAC C Series PLC.
The forced setting/resetting function in the SYSMAC C Series PLC holds the current ON/OFF status
without regard to the sequence program. However, when using the forced ON/OFF function described
here, the set/reset status of all the bit devices are released by turning ON/OFF the specified bit.
ON/OFF operation in the sequence program is valid after operating the forced ON/OFF in the GOT-
F900.
In the following version of the GOT, when the forced ON/OFF is operated, only the bit forcedly turned
ON/OFF is released.
15.7.3
Restriction in functions
In host link connection, the following functions of the GOT-F900 are disabled or restricted.
•
The switch function of the GOT-F900 (which sets a bit to ON or OFF) uses the host link FK command
(which sets/resets multi points forcedly).
•
Set values of the timer (T) and the counter (C) cannot be monitored or changed.
Mode of PLC at startup
Operation of GOT
Running mode
The GOT-F900 changes over the PLC from the running mode to the
monitor mode to enable data change.
Monitor mode
The PLC remains in the monitor mode, and data change is enabled.
Program mode
The PLC remains in the program mode, and data change is enabled.
GOT-F900
SYSMAC C Series
Operation
Forced OFF (RST)
Data OFF specification
Turn OFF the contact. Can be changed by sequence program.
Forced ON (SET)
Data ON specification
Turn ON the contact. Can be changed by sequence program.
−
Forced reset specification
Turn OFF the contact. Cannot be changed by sequence program.
−
Forced set specification
Turn ON the contact. Cannot be changed by sequence program.
−
Forced set/reset release
Forced status of all the contacts released. Can be changed by
the sequence program after the release.
GOT-F900
F930GOT
F930GOT-K
F940GOT
F940WGOT
Handy GOT
Compatible version
4.40
4.60
6.40
1.40
6.40
Summary of Contents for F920GOT-BBD-K-E
Page 4: ...GOT F900 SERIES CONNECTION ii ...
Page 6: ...GOT F900 SERIES CONNECTION iv ...
Page 38: ...GOT F900 SERIES CONNECTION Outline 2 2 10 MEMO ...
Page 70: ...GOT F900 SERIES CONNECTION Specifications 3 3 32 MEMO ...
Page 230: ...GOT F900 SERIES CONNECTION Connection of MELSEC F FX Series PLC 8 8 26 MEMO ...
Page 260: ...GOT F900 SERIES CONNECTION Connection of MELSEC A Series PLC 9 9 30 MEMO ...
Page 290: ...GOT F900 SERIES CONNECTION Connection of MELSEC QnA Series PLC 10 10 30 MEMO ...
Page 322: ...GOT F900 SERIES CONNECTION Connection of MELSEC Q Series PLC 11 11 32 MEMO ...
Page 376: ...GOT F900 SERIES CONNECTION Connection of FREQROL S500 E500 A500 Inverter 13 13 38 MEMO ...
Page 412: ...GOT F900 SERIES CONNECTION Connection of Microcomputer 14 14 36 MEMO ...
Page 554: ...GOT F900 SERIES CONNECTION Connection of Printer 21 21 8 MEMO ...
Page 590: ...GOT F900 SERIES CONNECTION Appendix 23 23 24 MEMO ...
Page 591: ......