GOT-F900 SERIES (CONNECTION)
Installation and Wiring of Handy GOT 5
5-18
5.4.3
Installation of External Cable
This section explains the procedure to install an optional external cable to the Handy GOT.
1) Remove rear cover
Rear face of Handy GOT
Remove four mounting screws "a)", and open the rear cover.
Installation screw M3(0.12")
×
8
Note:
Never remove any screw (among seven screws located around the
rear face of the Handy GOT) other than the mounting screws "a)".
If such a screw is removed, the waterproof ability may deteriorate
or failure may occur.
When rear cover is open
2) Connect an external cable
a) Insert an external cable into the installation hole C) of the main unit, and connect it to the ports A)
and B).
a)
Note
D )
C )
A )
B )
A)Power supply
connector (8 pins)
B) Connector for
communication and
operation switches
(20 pins)
C)Installation hole
D)Packing
Handy GOT
Handy GOT RH model
A)Power supply
connector
(CN1: 8 pins)
B) Connector for
communication and
operation switches
(CN2: 20 pins)
C)Connector for grip
switch (CN4: 5 pins)
D)Connector for
emergency stop
(CN5: 4 pins)
E) Installation hole
(CN6: 3 pins)
F) Installation hole
G)Packing
G )
F )
A )
B )
C )
E )
D )
W h e n p u s h i n g t h e
c a b l e t h r o u g h , m a k e
e a c h c o n n e c t o r f a c e
d o w n w a r d .
Summary of Contents for F920GOT-BBD-K-E
Page 4: ...GOT F900 SERIES CONNECTION ii ...
Page 6: ...GOT F900 SERIES CONNECTION iv ...
Page 38: ...GOT F900 SERIES CONNECTION Outline 2 2 10 MEMO ...
Page 70: ...GOT F900 SERIES CONNECTION Specifications 3 3 32 MEMO ...
Page 230: ...GOT F900 SERIES CONNECTION Connection of MELSEC F FX Series PLC 8 8 26 MEMO ...
Page 260: ...GOT F900 SERIES CONNECTION Connection of MELSEC A Series PLC 9 9 30 MEMO ...
Page 290: ...GOT F900 SERIES CONNECTION Connection of MELSEC QnA Series PLC 10 10 30 MEMO ...
Page 322: ...GOT F900 SERIES CONNECTION Connection of MELSEC Q Series PLC 11 11 32 MEMO ...
Page 376: ...GOT F900 SERIES CONNECTION Connection of FREQROL S500 E500 A500 Inverter 13 13 38 MEMO ...
Page 412: ...GOT F900 SERIES CONNECTION Connection of Microcomputer 14 14 36 MEMO ...
Page 554: ...GOT F900 SERIES CONNECTION Connection of Printer 21 21 8 MEMO ...
Page 590: ...GOT F900 SERIES CONNECTION Appendix 23 23 24 MEMO ...
Page 591: ......