GOT-F900 SERIES (CONNECTION)
Installation and Wiring of Handy GOT 5
5-16
5.4.2
Wiring between Handy GOT (RH model) operation switches and connected equipment
1) F940 Handy GOT
Connect the cable to
the port inside the
rear cover.
a)
b)
For the details, refer to 5.6.2.
To power supply and
operation switches
a)
c)
For the details, refer to 5.6.2.
To power supply and
operation switches
a)
d)
To computer link unit,
microcomputer board or
another company's PLC
To power supply and
operation switches
For the details, refer to 5.6.2.
To FX
0
/FX
0S
/FX
1S
/
FX
0N
/FX
1N
/FX
2N
/
FX
2NC
Series PLC
To FX/FX
2C
/A/QnA
Series PLC
For the details, refer to 5.4.3.
Name
Model name
Remarks
a) External cable
F9GT-RHCAB-3M(3m, 9' 10")
F9GT-RHCAB-6M(6m, 19' 8")
F9GT-RHCAB-10M(10m, 32' 10")
One side: 37-pin D-Sub
Cable outside diameter: 12.2mm(0.48")
b) Relay cable for PLC connection
F9GT-RHCAB2-150(1.5m, 4' 11")
For connecting FX Series CPU
PLC side: 8-pin MINI DIN
c) Relay cable for PLC connection
F9GT-RHCAB3-150(1.5m, 4' 11")
For connecting FX/A/QnA Series CPU
PLC side: 25-pin D-Sub
d) Relay cable for PLC connection
Prepared by user
P O W
E R
G R I P
S W
When connecting via RS-232C ports, make sure that the distance between the Handy GOT and PLC
is 11.5m (37' 9") or less.
CN1(8-pin)
CN2(20-pin)
CN4(5-pin)
CN5(4-pin)
CN6(3-pin)
CN7(2-pin)
CN1:For power supply
CN2:For communication
CN4:For grip switch
CN5:For emergency stop switch
CN6:For keylock switch
CN7:Not to be wired
Summary of Contents for F920GOT-BBD-K-E
Page 4: ...GOT F900 SERIES CONNECTION ii ...
Page 6: ...GOT F900 SERIES CONNECTION iv ...
Page 38: ...GOT F900 SERIES CONNECTION Outline 2 2 10 MEMO ...
Page 70: ...GOT F900 SERIES CONNECTION Specifications 3 3 32 MEMO ...
Page 230: ...GOT F900 SERIES CONNECTION Connection of MELSEC F FX Series PLC 8 8 26 MEMO ...
Page 260: ...GOT F900 SERIES CONNECTION Connection of MELSEC A Series PLC 9 9 30 MEMO ...
Page 290: ...GOT F900 SERIES CONNECTION Connection of MELSEC QnA Series PLC 10 10 30 MEMO ...
Page 322: ...GOT F900 SERIES CONNECTION Connection of MELSEC Q Series PLC 11 11 32 MEMO ...
Page 376: ...GOT F900 SERIES CONNECTION Connection of FREQROL S500 E500 A500 Inverter 13 13 38 MEMO ...
Page 412: ...GOT F900 SERIES CONNECTION Connection of Microcomputer 14 14 36 MEMO ...
Page 554: ...GOT F900 SERIES CONNECTION Connection of Printer 21 21 8 MEMO ...
Page 590: ...GOT F900 SERIES CONNECTION Appendix 23 23 24 MEMO ...
Page 591: ......