GOT-F900 SERIES (CONNECTION)
Connection of Two or More GOT Units 7
7-11
1
In
tr
o
d
u
c
tio
n
2
Ou
tl
in
e
3
S
p
eci
fic
a
ti
on
s
4
in
st
a
ll
a
ti
o
n
an
d W
iri
ng
o
f
F9
40
G
O
T
5
in
s
ta
llat
io
n
an
d W
ir
in
g
of
Ha
n
d
y
GO
T
6
C
o
nne
c
ti
o
n of
P
e
ri
ph
er
al
Eq
ui
pm
en
t
7
C
o
nn
ect
io
n o
f
T
w
o or
Mor
e
GO
T
U
n
it
s
8
C
o
nn
ec
ti
o
n
of
M
E
LSEC-
F
F
X
Se
ri
e
s
PLC
9
C
o
n
n
e
c
ti
on o
f
M
E
L
SEC-
A
Se
ri
e
s
PLC
10
C
o
n
n
e
c
ti
on
of
M
E
L
SEC-
Q
n
A
Se
ri
e
s
PLC
7.5.2
Transfer of sequence program and use of monitor
This section explains the restriction on sequence program transfer and device monitoring through a
personal computer connected to a GOT unit while two or more GOT units are connected. (Excluding
microcomputer connection)
1) When a personal computer is connected to the last GOT unit
Even if there is an unused RS-232C connector in the last connected GOT unit, connection and use
of a personal computer are disabled for the following reasons.
a) Because the response is slow during device monitoring, this connection cannot be recommended
for practical use.
b) Because the communication time is long during program transfer or monitoring, a communication
error may occur in the software installed in the personal computer.
2) When a personal computer is connected to the F940WGOT
The F940WGOT is equipped with 2 channels of RS-232C connectors. However, if the F940WGOT is
connected to a GOT unit and a personal computer at the same time, sequence program transfer and
monitoring are disabled.
The two-port interface function is available only for either the function to connect two or more GOT
units or the program transfer/monitoring function. (Use of these two functions at the same time is not
allowed.)
PLC
GOT-F900
GOT-F900
GOT-F900
RS-232C
FX/WIN
GX Developer
PLC
F940WGOT
GOT-F900
GOT-F900
RS-232C
FX/WIN
GX Developer
Summary of Contents for F920GOT-BBD-K-E
Page 4: ...GOT F900 SERIES CONNECTION ii ...
Page 6: ...GOT F900 SERIES CONNECTION iv ...
Page 38: ...GOT F900 SERIES CONNECTION Outline 2 2 10 MEMO ...
Page 70: ...GOT F900 SERIES CONNECTION Specifications 3 3 32 MEMO ...
Page 230: ...GOT F900 SERIES CONNECTION Connection of MELSEC F FX Series PLC 8 8 26 MEMO ...
Page 260: ...GOT F900 SERIES CONNECTION Connection of MELSEC A Series PLC 9 9 30 MEMO ...
Page 290: ...GOT F900 SERIES CONNECTION Connection of MELSEC QnA Series PLC 10 10 30 MEMO ...
Page 322: ...GOT F900 SERIES CONNECTION Connection of MELSEC Q Series PLC 11 11 32 MEMO ...
Page 376: ...GOT F900 SERIES CONNECTION Connection of FREQROL S500 E500 A500 Inverter 13 13 38 MEMO ...
Page 412: ...GOT F900 SERIES CONNECTION Connection of Microcomputer 14 14 36 MEMO ...
Page 554: ...GOT F900 SERIES CONNECTION Connection of Printer 21 21 8 MEMO ...
Page 590: ...GOT F900 SERIES CONNECTION Appendix 23 23 24 MEMO ...
Page 591: ......