GOT-F900 SERIES (CONNECTION)
Connection of MELSEC-F FX Series PLC 8
8-23
1
In
tr
o
d
u
c
tio
n
2
Ou
tl
in
e
3
S
p
eci
fic
a
ti
on
s
4
in
st
a
ll
a
ti
o
n
an
d W
iri
ng
o
f
F9
40
G
O
T
5
in
s
ta
llat
io
n
an
d W
ir
in
g
of
Ha
n
d
y
GO
T
6
C
o
nne
c
ti
o
n o
f
P
e
ri
ph
er
al
Eq
ui
pm
en
t
7
C
o
nn
ect
io
n of
T
w
o or
Mor
e
GO
T
U
n
it
s
8
Co
n
n
e
c
ti
o
n
o
f
M
E
LSEC-
F
F
X
Se
ri
e
s
PLC
9
C
o
n
n
e
c
ti
on of
M
E
L
SEC-
A
Se
ri
e
s
PLC
10
C
onn
ec
ti
o
n
of
M
E
L
SEC-
Q
n
A
Se
ri
e
s
PLC
"DATA IS NOT
FOUND." is
displayed on the
GOT-F900 screen.
There is not data because the unit is new or the
memory clear has been executed.
• Cause
There is no screen data.
• Countermeasures
Write the screen data using the screen creation
software.
−
Earlier
than
6.00
Earlier
than
4.00
−
A device that does not exist in the FX Series PLC was
referenced. (Example: While an FX
0S
Series PLC is
connected, a device exits only in the FX-**M*-** Series
PLC is specified for numeric input.)
• Cause
On the head screen, a nonexistent device in the
connected FX Series PLC is specified.
(The head screen is the screen No. 1 in the GT
Designer, and the screen No. 0 in the DU/WIN.)
• Countermeasures
Check the devices used on the head screen.
While the FX Series PLC is not connected, the
connection mode for the FX-**M*-** Series PLC is
selected.
• Cause
Check for the FX-**M*-** or FX
2N
Series was
executed, the connection mode was automatically
changed over, then the device range was checked.
This error occurs when the device range set on the
head screen is beyond the range for the FX
2
Series.
(The head screen is the screen No. 1 in the GT
Designer, and the screen No. 0 in the DU/WIN.)
• Countermeasures
Connect the PLC.
There is not data because the unit is new or the
memory clear has been executed.
• Cause
There is no screen data.
• Countermeasures
Write the screen data using the screen creation
software.
From
first
product
6.00 or
later
4.00 or
later
From
first
product
"CAN NOT WRITE
TO PLC MEMORY."
is displayed on the
GOT-F900 screen.
Programs and device set values of the FX Series PLC
cannot be changed.
• Causes
The write-protect switch of the memory cassette is set
to ON. PLC Password protection is on.
• Countermeasures
Set the write-protect switch to OFF.
Enter the keywords by "SELECT MODE"-"OTHER
MODE"-"ENTRY CODE".
Earlier
than
1.10
Earlier
than
6.10
Earlier
than
4.10
−
Contents of trouble
Check points and countermeasures
OS version
F940W
F940
F930
F920
Summary of Contents for F920GOT-BBD-K-E
Page 4: ...GOT F900 SERIES CONNECTION ii ...
Page 6: ...GOT F900 SERIES CONNECTION iv ...
Page 38: ...GOT F900 SERIES CONNECTION Outline 2 2 10 MEMO ...
Page 70: ...GOT F900 SERIES CONNECTION Specifications 3 3 32 MEMO ...
Page 230: ...GOT F900 SERIES CONNECTION Connection of MELSEC F FX Series PLC 8 8 26 MEMO ...
Page 260: ...GOT F900 SERIES CONNECTION Connection of MELSEC A Series PLC 9 9 30 MEMO ...
Page 290: ...GOT F900 SERIES CONNECTION Connection of MELSEC QnA Series PLC 10 10 30 MEMO ...
Page 322: ...GOT F900 SERIES CONNECTION Connection of MELSEC Q Series PLC 11 11 32 MEMO ...
Page 376: ...GOT F900 SERIES CONNECTION Connection of FREQROL S500 E500 A500 Inverter 13 13 38 MEMO ...
Page 412: ...GOT F900 SERIES CONNECTION Connection of Microcomputer 14 14 36 MEMO ...
Page 554: ...GOT F900 SERIES CONNECTION Connection of Printer 21 21 8 MEMO ...
Page 590: ...GOT F900 SERIES CONNECTION Appendix 23 23 24 MEMO ...
Page 591: ......