Connection of Two or More GOT Units 7
7-1
1
In
tr
o
d
u
c
tio
n
2
Ou
tl
in
e
3
S
p
eci
fic
a
ti
on
s
4
in
st
a
ll
a
ti
o
n
an
d W
iri
ng
o
f
F9
40
G
O
T
5
in
s
ta
llat
io
n
an
d W
ir
in
g
of
Ha
n
d
y
GO
T
6
C
o
nne
c
ti
o
n of
P
e
ri
ph
er
al
Eq
ui
pm
en
t
7
C
o
nn
ect
io
n o
f
T
w
o or
Mor
e
GO
T
U
n
it
s
8
C
o
nn
ec
ti
o
n
of
M
E
LSEC-
F
F
X
Se
ri
e
s
PLC
9
C
o
n
n
e
c
ti
on o
f
M
E
L
SEC-
A
Se
ri
e
s
PLC
10
C
o
n
n
e
c
ti
on
of
M
E
L
SEC-
Q
n
A
Se
ri
e
s
PLC
7.
Connection of Two or More GOT Units
This chapter explains the setting method, the cable connection diagram and cautions when two or more
GOT units are connected.
Connection Procedure
1.
Preparation
2.
Setting
3.
Others
7.1
System Condition
When connecting two or more GOT units, check the COM port designation, the OS version of the GOT-
F900 and applicable version of the screen creation software.
Have in mind that connection may not be allowed if the connected PLC (FX/A/QnA/Q Series PLC or
microcomputer) is the CPU direct connection type or the OS version of the GOT-F900 Series does not
match.
For OS version compatible with Q multiple PLC system, refer to Chapter 11.
*1 Only one Handy GOT unit can be connected at the end.
Item name
Description
Reference
System Condition
You can learn the connection availability as well as the version of the
GOT-F900 OS and the screen creation software.
7.1
System Configuration for
Two or More GOT Units
You can select the GOT configuration and proper cables.
7.2
Rules in Configuration
You can learn the connection procedure in accordance with the
specifications of the interface built in the GOT.
7.3
Connection of Four or
More Display Units
This section introduces connection of two or more GOT units and the
means to use satisfactorily the peripheral equipment for PLC.
7.4
Cautions on Connecting
Two or More GOT Units
You can learn the restrictions in connecting two or more GOT units.
7.5
Item name
Description
Reference
Setting of Connected
Equipment for GOT
You can set the connection type (RS-232C/RS-422) of the second and
later GOT units.
7.6
Item name
Description
Reference
Cable Diagram
Cable diagrams for two or more GOT unit connection.
7.7
Troubleshooting
Description of errors and how to fix them.
7.8
GOT-F900 Series
COM port to which GOT
can be connected
OS version of GOT-F900
RS-422
RS-232C
FXCPU
ACPU
QnACPU
QCPU
Microcomputer
F920GOT-K
−
−
−
−
−
−
−
F930GOT
$
$
1.00
1.00
2.00
2.20
3.00
F930GOT-K
$
$
4.60
4.60
4.60
4.60
4.60
F940GOT
$
$
1.00
1.00
3.00
4.10
5.00
F940WGOT
$
$
F940 Handy GOT
$
*1
−
F943 Handy GOT
−
$
*1
Screen creation
software
GT Designer
SW-1A
SW-1A
SW-2A
SW-4F
SW-1A
DU/WIN
2.00
2.00
2.30
2.40
2.00
GOT-F900 SERIES (CONNECTION)
Summary of Contents for F920GOT-BBD-K-E
Page 4: ...GOT F900 SERIES CONNECTION ii ...
Page 6: ...GOT F900 SERIES CONNECTION iv ...
Page 38: ...GOT F900 SERIES CONNECTION Outline 2 2 10 MEMO ...
Page 70: ...GOT F900 SERIES CONNECTION Specifications 3 3 32 MEMO ...
Page 230: ...GOT F900 SERIES CONNECTION Connection of MELSEC F FX Series PLC 8 8 26 MEMO ...
Page 260: ...GOT F900 SERIES CONNECTION Connection of MELSEC A Series PLC 9 9 30 MEMO ...
Page 290: ...GOT F900 SERIES CONNECTION Connection of MELSEC QnA Series PLC 10 10 30 MEMO ...
Page 322: ...GOT F900 SERIES CONNECTION Connection of MELSEC Q Series PLC 11 11 32 MEMO ...
Page 376: ...GOT F900 SERIES CONNECTION Connection of FREQROL S500 E500 A500 Inverter 13 13 38 MEMO ...
Page 412: ...GOT F900 SERIES CONNECTION Connection of Microcomputer 14 14 36 MEMO ...
Page 554: ...GOT F900 SERIES CONNECTION Connection of Printer 21 21 8 MEMO ...
Page 590: ...GOT F900 SERIES CONNECTION Appendix 23 23 24 MEMO ...
Page 591: ......