1) Switch assignment
The figure below shows the switch assignment. Each switch is expressed in abbreviations as follows.
Switches requiring external wiring
The following switches have to be connected to the PLC or external input equipment through the
operation switch connector.
-
Operation switches
-
Emergency stop switch
-
Grip switch
-
Keylock switch
LEDs not requiring external wiring
Because the following switch and LEDs are connected to the display unit CPU and ready for serial
communication with the PLC through the communication port, they do not have to be wired.
-
Indicator LED for grip switch
-
Indicator LEDs for operation switches
2) Internal wiring of switches
Each switch on the previous page is wired inside the Handy GOT as shown below.
The connectors CN1 to CN5 (except CN3) are connected to the PLC via an external cable (F9GT-
RHCAB-
"
M).
Abbreviation
Name
Reference
SW1~SW4
Operation switches
5.9.1
ES1
Emergency stop switch
5.10
KSW1,KSW2
Keylock switch
5.13
L1~L4
Indicator LEDs for
operation switches
5.9.1
L5
Indicator LED for grip
switch
5.12.2
DSW1,DSW2
Grip switch
5.12
G r i p
s w i t c h
P O W E R
G R I P S W
S W 1 S W 2 S W 3 S W 4
E S 1
L 1
L 2
L 3
L 4
L 5
K S W
CPU memory
LCD panel
Touch switch circuit
Display circuit
Serial
communication
unit
CPU/communication circuit
RS-232C
(for personal
computer)
DC24V+
DC24G
FG
RS-422 or RS-232C
(for externally
connected
equipment)
Operation
switches
SW1
SW2
SW3
SW4
SW-COM
Emergency
stop switch
ES1-1
ES1-2
CN5
DSW1
DSW2
CN4
CN2
CN2
CN1
Grip switch
ES1-1
ES1-2
Keylock
switch
KSW-2
KSW-C
KSW-1
CN6
Power
supply
Power
supply
circuit
CN3
L1(SW1)
L2(SW2)
L3(SW3)
L4(SW4)
L5
(GRIP SW)
Grip switch
Indicator LEDs
for operation
switches
To ex
te
rnal
c
onnec
ti
on c
a
bl
e
I/O
in
te
rf
a
c
e
Summary of Contents for F920GOT-BBD-K-E
Page 4: ...GOT F900 SERIES CONNECTION ii ...
Page 6: ...GOT F900 SERIES CONNECTION iv ...
Page 38: ...GOT F900 SERIES CONNECTION Outline 2 2 10 MEMO ...
Page 70: ...GOT F900 SERIES CONNECTION Specifications 3 3 32 MEMO ...
Page 230: ...GOT F900 SERIES CONNECTION Connection of MELSEC F FX Series PLC 8 8 26 MEMO ...
Page 260: ...GOT F900 SERIES CONNECTION Connection of MELSEC A Series PLC 9 9 30 MEMO ...
Page 290: ...GOT F900 SERIES CONNECTION Connection of MELSEC QnA Series PLC 10 10 30 MEMO ...
Page 322: ...GOT F900 SERIES CONNECTION Connection of MELSEC Q Series PLC 11 11 32 MEMO ...
Page 376: ...GOT F900 SERIES CONNECTION Connection of FREQROL S500 E500 A500 Inverter 13 13 38 MEMO ...
Page 412: ...GOT F900 SERIES CONNECTION Connection of Microcomputer 14 14 36 MEMO ...
Page 554: ...GOT F900 SERIES CONNECTION Connection of Printer 21 21 8 MEMO ...
Page 590: ...GOT F900 SERIES CONNECTION Appendix 23 23 24 MEMO ...
Page 591: ......