GOT-F900 SERIES (CONNECTION)
Specifications 3
3-13
1
In
tr
o
d
u
c
tio
n
2
Ou
tl
in
e
3
S
p
eci
fic
a
ti
on
s
4
in
st
a
ll
a
ti
o
n
an
d W
iri
ng
o
f
F9
40
G
O
T
5
in
s
ta
llat
io
n
an
d W
ir
in
g
of
Ha
n
d
y
GO
T
6
C
o
nne
c
ti
o
n of
P
e
ri
ph
er
al
Eq
ui
pm
en
t
7
C
o
nn
ect
io
n o
f
T
w
o or
Mor
e
GO
T
U
n
it
s
8
C
o
nn
ec
ti
o
n
of
M
E
LSEC-
F
F
X
Se
ri
e
s
PLC
9
C
o
n
n
e
c
ti
on o
f
M
E
L
SEC-
A
Se
ri
e
s
PLC
10
C
o
n
n
e
c
ti
on
of
M
E
L
SEC-
Q
n
A
Se
ri
e
s
PLC
3.3
Device Names Which can be Monitored
This section explains the device range of the PLC available in the GOT-F900. The maximum device
range which can be set in the screen creation software is shown here. The device specifications vary
depending on the model of the PLC even if the series name is equivalent. (Example: In the FX Series,
the FX
1N
PLC has fewer devices than in the FX
2N
PLC.)
When looking at the table, change the device range shown in the table with the device range available in
the actually connected PLC.
3.3.1
Devices in GOT-F900
The table below shows intrinsic devices built in the GOT-F900.
Because these internal devices have no relevance to the devices in the connected PLC or the memory
of the microcomputer board, they can be used without regard to the connected equipment.
These internal devices in the GOT-F900 can be rewritten by the status monitoring function, the switch
function and the numeric value input function, and used for lamp indicator, numeric value display, switch
condition, etc.
Available screen creation software
GT Designer2 and GT Designer from the first version
DU/WIN from Version 2.50 and later
Allocation of devices for internal processing
-
GB 0 to GB 131 and GD 0 to GD 99 are used for the processing inside the GOT-F900.
Note, however, that the devices with functions shown below are available for user use.
Device name
Available range
Device number
representation
Bit
device
GB (GOT internal device)
GB0 to GB131
Not available except devices in table
below
Decimal
GB132 to GB255
Available
GB256 to GB1023
Available (excluding the F920GOT-K)
Word
device
GD (GOT internal device)
GD0 to GD99
Not available except devices in table
below
Decimal
GD100 to GD127
Available
GD128 to GD1023 Available (excluding the F920GOT-K)
Device
Function
Device
Function
GD0
Display of current time (second)
*2
GB0 to GB12
Not to be used
GD1
Display of current time (minute)
*2
GB13
Communication error
GD2
Display of current time (hour)
*2
GB14,GB15
Not to be used
GD3
Display of current time (day)
*2
GB16
Buzzer (Issued once)
*1
GD4
Display of current time (month)
*2
GB17
Buzzer (Issued three times)
*1
GD5
Display of current time (year)
*2
GB18
Buzzer (Issued continuously)
*1
GD6
Display of current time (day of week)
*2
GB19 to 131
Not to be used
GD7
Not to be used
GB132 to GB1023 For user's use
GD8,GD9
Upper limit of input numerical value (32 bit)
*1 Buzzer is available in the following OS.
F940WGOT Ver. 1.40 or later
F940GOT
Ver. 6.40 or later
F930GOT
Ver. 4.40 or later
F930GOT-K Ver. 4.60 or later (From first product)
F920GOT-K Ver. 1.00 or later (From first product)
Handy GOT Ver. 6.40 or later
GD10,GD11
Lower limit of input numerical value (32 bit)
GD12
Numerical value, Ascii input
GD13 to GD99
Not to be used
GD100 to GD1023 For user's use
*2 Which cannot be input or changed
Summary of Contents for F920GOT-BBD-K-E
Page 4: ...GOT F900 SERIES CONNECTION ii ...
Page 6: ...GOT F900 SERIES CONNECTION iv ...
Page 38: ...GOT F900 SERIES CONNECTION Outline 2 2 10 MEMO ...
Page 70: ...GOT F900 SERIES CONNECTION Specifications 3 3 32 MEMO ...
Page 230: ...GOT F900 SERIES CONNECTION Connection of MELSEC F FX Series PLC 8 8 26 MEMO ...
Page 260: ...GOT F900 SERIES CONNECTION Connection of MELSEC A Series PLC 9 9 30 MEMO ...
Page 290: ...GOT F900 SERIES CONNECTION Connection of MELSEC QnA Series PLC 10 10 30 MEMO ...
Page 322: ...GOT F900 SERIES CONNECTION Connection of MELSEC Q Series PLC 11 11 32 MEMO ...
Page 376: ...GOT F900 SERIES CONNECTION Connection of FREQROL S500 E500 A500 Inverter 13 13 38 MEMO ...
Page 412: ...GOT F900 SERIES CONNECTION Connection of Microcomputer 14 14 36 MEMO ...
Page 554: ...GOT F900 SERIES CONNECTION Connection of Printer 21 21 8 MEMO ...
Page 590: ...GOT F900 SERIES CONNECTION Appendix 23 23 24 MEMO ...
Page 591: ......