GOT-F900 SERIES (CONNECTION)
Connection of MELSEC-Q Series PLC 11
11-15
11
C
o
n
n
e
c
ti
on
of
ME
L
S
E
C
-Q
Se
ri
e
s
PL
C
12
Co
n
n
e
c
ti
o
n
o
f
FX Se
ri
e
s
Po
s
it
io
n
in
g
13
C
o
n
n
e
c
ti
on o
f
FR
EQ
R
O
L
In
ve
rt
er
14
C
onn
ec
ti
o
n
of
Mi
cr
o
c
o
m
-
put
e
r
15
C
o
nn
ec
ti
o
n
of
S
YSM
A
C
C
Se
ri
e
s
PL
C
16
C
o
nne
c
ti
o
n of
F
L
EX-
PC N
Se
ri
e
s
PL
C
17
C
o
nn
ect
io
n o
f
M
a
c
h
in
e
C
on-
troll
e
r
18
C
o
nn
ec
ti
o
n
of
FP
Se
ri
e
s
PL
C
19
C
o
n
n
e
c
ti
on o
f
S
L
C
500
Se
ri
e
s
PLC
20
C
o
n
n
e
c
ti
on
of
SI
M
A
T
IC S7
Se
ri
e
s
PLC
11.5.4
Caution when setting screen creation software
QCPU of function version -B or later (except Q00JCPU, Q00CPU, or Q01CPU) is compatible with the
multiple PLC system with 4 GOT units maximum.
When two or more QCPU are attached to the main unit, the configuration is called a multiple PLC
system, and monitoring of other CPU (number specified) from the CPU connected with the GOT-F900 is
enabled.
According to the PLC type specified in the screen creation software, the CPU which can be monitored is
determined as follows
1) In one unit CPU configuration
In the screen creation software, select MELSEC-QnA, A for PLC type.
2) In multiple PLC system
In the screen creation software, select MELSEC-Q (Multi) for PLC type.
PLC type in screen creation
software and GOT
CPU connected with
GOT-F900
Other CPU
Serial communication unit
MELSEC-QnA, Q
$
−
Only control PLC monitored
MELSEC-Q (Multi)
−
−
−
PLC type in screen creation
software and GOT
CPU connected with
GOT-F900
Other CPU
Serial communication unit
MELSEC-QnA, Q
$
−
Only control PLC monitored
MELSEC-Q (Multi)
$
$
$
GOT-F900
Control PLC
Other CPU
QCPU 4 units
PLC number of CPU
1 2 3 4
Summary of Contents for F920GOT-BBD-K-E
Page 4: ...GOT F900 SERIES CONNECTION ii ...
Page 6: ...GOT F900 SERIES CONNECTION iv ...
Page 38: ...GOT F900 SERIES CONNECTION Outline 2 2 10 MEMO ...
Page 70: ...GOT F900 SERIES CONNECTION Specifications 3 3 32 MEMO ...
Page 230: ...GOT F900 SERIES CONNECTION Connection of MELSEC F FX Series PLC 8 8 26 MEMO ...
Page 260: ...GOT F900 SERIES CONNECTION Connection of MELSEC A Series PLC 9 9 30 MEMO ...
Page 290: ...GOT F900 SERIES CONNECTION Connection of MELSEC QnA Series PLC 10 10 30 MEMO ...
Page 322: ...GOT F900 SERIES CONNECTION Connection of MELSEC Q Series PLC 11 11 32 MEMO ...
Page 376: ...GOT F900 SERIES CONNECTION Connection of FREQROL S500 E500 A500 Inverter 13 13 38 MEMO ...
Page 412: ...GOT F900 SERIES CONNECTION Connection of Microcomputer 14 14 36 MEMO ...
Page 554: ...GOT F900 SERIES CONNECTION Connection of Printer 21 21 8 MEMO ...
Page 590: ...GOT F900 SERIES CONNECTION Appendix 23 23 24 MEMO ...
Page 591: ......