GOT-F900 SERIES (CONNECTION)
Specifications 3
3-3
1
In
tr
o
d
u
c
tio
n
2
Ou
tl
in
e
3
S
p
eci
fic
a
ti
on
s
4
in
st
a
ll
a
ti
o
n
an
d W
iri
ng
o
f
F9
40
G
O
T
5
in
s
ta
llat
io
n
an
d W
ir
in
g
of
Ha
n
d
y
GO
T
6
C
o
nne
c
ti
o
n of
P
e
ri
ph
er
al
Eq
ui
pm
en
t
7
C
o
nn
ect
io
n o
f
T
w
o or
Mor
e
GO
T
U
n
it
s
8
C
o
nn
ec
ti
o
n
of
M
E
LSEC-
F
F
X
Se
ri
e
s
PLC
9
C
o
n
n
e
c
ti
on o
f
M
E
L
SEC-
A
Se
ri
e
s
PLC
10
C
o
n
n
e
c
ti
on
of
M
E
L
SEC-
Q
n
A
Se
ri
e
s
PLC
$
: Can connect
: Cannot connect
*1 Excluding the 920 system
*2 Excluding the 5 V type F920GOT-K.
MELSEC-Q Series (CPU direct connection)
Connection type name [QCPU direct connection]
Connection to programming port in Q CPU
Q02CPU, Q02HCPU, Q06HCPU, Q12HCPU,
Q25HCPU
RS-232C
1.00
or later
4.10
or later
2.20
or later
1.00
or later
$
*1
11.2.1
Q00JCPU,Q00CPU,Q01CPU
RS-232C
1.30
or later
6.30
or later
4.30
or later
1.00
or later
$
*1
11.2.1
MELSEC-Q Series (CPU direct connection)
Connection type name [QCPU direct connection]
Connection to serial communication unit
QJ71C24
RS-422
1.00
or later
4.10
or later
2.20
or later
1.20
*2
or later
11.2.2
QJ71C24, QJ71C24-R2
RS-232C
11.2.3
MELSEC-Q Series (CPU direct connection)
Connection type name [QCPU direct connection]
(Q multiple PLC system Ver. B or later)
Connection to programming port in Q CPU
Q02CPU, Q02HCPU, Q06HCPU, Q12HCPU,
Q25HCPU
RS-232C
1.30
or later
6.30
or later
4.30
or later
1.00
or later
$
*1
11.2.1
Connection to serial communication unit
QJ71C24
RS-422
1.30
or later
6.30
or later
4.30
or later
1.20
*2
or later
11.2.2
QJ71C24, QJ71C24-R2
RS-232C
11.2.3
FX Series positioning unit (CPU direct connection)
Connection type name [GM direct connection]
Connection to programming port in GM CPU
FX
2N
-10GM, FX
2N
-20GM, FX-10GM, FX-20GM,
E-20GM
RS-422
1.10
or later
6.10
or later
4.10
or later
12.2.1
FREQROL Series inverter (CPU direct connection)
Connection type name [INV direct connection]
Connection to computer link (PU port, etc.)
S500 Series (R-485 port built-in type only)
A500 Series (PU port, FR-A5NR)
E500 Series (PU port)
RS-422
1.10
or later
6.10
or later
4.10
or later
13.2.1
Connected equipment name and series
name
RS-232C/
RS-422
OS version
Connection of two
or more GOT units
Reference
940W
system
940
system
930
system
920
system
Summary of Contents for F920GOT-BBD-K-E
Page 4: ...GOT F900 SERIES CONNECTION ii ...
Page 6: ...GOT F900 SERIES CONNECTION iv ...
Page 38: ...GOT F900 SERIES CONNECTION Outline 2 2 10 MEMO ...
Page 70: ...GOT F900 SERIES CONNECTION Specifications 3 3 32 MEMO ...
Page 230: ...GOT F900 SERIES CONNECTION Connection of MELSEC F FX Series PLC 8 8 26 MEMO ...
Page 260: ...GOT F900 SERIES CONNECTION Connection of MELSEC A Series PLC 9 9 30 MEMO ...
Page 290: ...GOT F900 SERIES CONNECTION Connection of MELSEC QnA Series PLC 10 10 30 MEMO ...
Page 322: ...GOT F900 SERIES CONNECTION Connection of MELSEC Q Series PLC 11 11 32 MEMO ...
Page 376: ...GOT F900 SERIES CONNECTION Connection of FREQROL S500 E500 A500 Inverter 13 13 38 MEMO ...
Page 412: ...GOT F900 SERIES CONNECTION Connection of Microcomputer 14 14 36 MEMO ...
Page 554: ...GOT F900 SERIES CONNECTION Connection of Printer 21 21 8 MEMO ...
Page 590: ...GOT F900 SERIES CONNECTION Appendix 23 23 24 MEMO ...
Page 591: ......