GOT-F900 SERIES (CONNECTION)
Connection of SIMATIC S7-200/300/400 Series PLC (Manufactured by Siemens AG) 20
20-9
11
C
o
n
n
e
c
ti
on
of
ME
L
S
E
C
-Q
Se
ri
e
s
PL
C
12
Co
n
n
e
c
ti
o
n
o
f
FX Se
ri
e
s
Po
s
it
io
n
in
g
13
C
o
n
n
e
c
ti
on o
f
FR
EQ
R
O
L
In
ve
rt
er
14
C
onn
ec
ti
o
n
of
Mi
cr
o
c
o
m
-
put
e
r
15
C
o
nn
ec
ti
o
n
of
S
YSM
A
C
C
Se
ri
e
s
PL
C
16
C
o
nne
c
ti
o
n of
F
L
EX-
PC N
Se
ri
e
s
PL
C
17
C
o
nn
ect
io
n o
f
M
a
c
h
in
e
C
on-
troll
e
r
18
C
o
nn
ec
ti
o
n
of
FP
Se
ri
e
s
PL
C
19
C
o
n
n
e
c
ti
on o
f
S
L
C
500
Se
ri
e
s
PLC
20
C
o
n
n
e
c
ti
on
of
SI
M
A
T
IC S7
Se
ri
e
s
PLC
20.5
Device Specification Method
This section explains the format used to specify devices of the SIMATIC S7-200/300/400 Series.
For the device range which can be set in the GOT-F900, refer to section 3.3.
20.5.1
Device Format in SIMATIC S7-200
1) Bit device (except timer and counter)
a) Specify the device symbol in an alphabet.
b) Specify the device (byte) number corresponding to each device.
c) Specify the bit position in a 1-digit number (0 to 7).
Example: To specify "M20.5"
Device symbol ................ M
Device (byte) number ..... 20
Bit position ...................... 5
2) Bit device and word device (timer and counter)
The specification method is equivalent to that of the bit device except "c) Specify the bit position".
a) Specify the device symbol in an alphabet.
b) Specify the device (byte) number corresponding to each device.
Example: To specify Timer (T) (present value) "T250"
Device symbol ................ T
Device (byte) number ..... 250
3) Word device (except timer and counter)
a) Specify the device symbol in two or three alphabets.
b) Specify the device (byte) number corresponding to each device.
Example: To specify Special memory "MW25"
Device symbol ................ MW
Device (byte) number ..... 25
*1 Except the high speed counter (HC)
GT Designer version SW5-P (5.13P) or later
DU/WIN version 2.60 or later
Bit device
(except timer and
counter)
Bit device
(except timer and
counter)
Bit device
Word device
(timer and counter)
Bit device
Word device
(timer and counter)
Word device
(except timer and
counter)
Word device
(except timer and
counter)
GT Designer
DU/WIN
1- to 4-digit decimal number (without 0 suppression) 1- to 4-digit decimal number (with 0 suppression)
GT Designer
DU/WIN
1- to 4-digit decimal number (with 0 suppression)
1- to 4-digit decimal number (with 0 suppression)
GT Designer
DU/WIN
1- to 4-digit decimal number (with 0 suppression)
(Only an even number can be specified.
*1
)
1- to 4-digit decimal number (with 0 suppression)
(Only an even number can be specified.
*1
)
▲
####
"
a) b) c)
▲
####
.
"
a) b) c)
▲
####
a) b)
▲
####
a) b)
▲
####
a) b)
▲
####
a) b)
Summary of Contents for F920GOT-BBD-K-E
Page 4: ...GOT F900 SERIES CONNECTION ii ...
Page 6: ...GOT F900 SERIES CONNECTION iv ...
Page 38: ...GOT F900 SERIES CONNECTION Outline 2 2 10 MEMO ...
Page 70: ...GOT F900 SERIES CONNECTION Specifications 3 3 32 MEMO ...
Page 230: ...GOT F900 SERIES CONNECTION Connection of MELSEC F FX Series PLC 8 8 26 MEMO ...
Page 260: ...GOT F900 SERIES CONNECTION Connection of MELSEC A Series PLC 9 9 30 MEMO ...
Page 290: ...GOT F900 SERIES CONNECTION Connection of MELSEC QnA Series PLC 10 10 30 MEMO ...
Page 322: ...GOT F900 SERIES CONNECTION Connection of MELSEC Q Series PLC 11 11 32 MEMO ...
Page 376: ...GOT F900 SERIES CONNECTION Connection of FREQROL S500 E500 A500 Inverter 13 13 38 MEMO ...
Page 412: ...GOT F900 SERIES CONNECTION Connection of Microcomputer 14 14 36 MEMO ...
Page 554: ...GOT F900 SERIES CONNECTION Connection of Printer 21 21 8 MEMO ...
Page 590: ...GOT F900 SERIES CONNECTION Appendix 23 23 24 MEMO ...
Page 591: ......