Connection of MELSEC-A Series PLC 9
9-1
1
In
tr
o
d
u
c
tio
n
2
Ou
tl
in
e
3
S
p
eci
fic
a
ti
on
s
4
in
st
a
ll
a
ti
o
n
an
d W
iri
ng
o
f
F9
40
G
O
T
5
in
s
ta
llat
io
n
an
d W
ir
in
g
of
Ha
n
d
y
GO
T
6
C
o
nne
c
ti
o
n of
P
e
ri
ph
er
al
Eq
ui
pm
en
t
7
C
o
nn
ect
io
n o
f
T
w
o or
Mor
e
GO
T
U
n
it
s
8
C
o
nn
ec
ti
o
n
of
M
E
L
SEC-
F
FX
Se
ri
e
s
PL
C
9
C
o
n
n
e
c
ti
on of
M
E
L
SEC-
A
Se
ri
e
s
PLC
10
C
onn
ec
ti
o
n
of
M
E
L
SEC-
Q
n
A
Se
ri
e
s
PLC
9.
Connection of MELSEC-A Series PLC
This chapter explains connection of the GOT-F900 Series display unit to the CPU unit or the computer
link unit of the A Series PLC.
The same procedure is taken when connecting to the CPU of the motion controller (in which CPU direct
connection is available).
Connection Procedure
This section introduces the procedure to connect the GOT-F900 to the A Series PLC.
1.
Preparation
2.
Setting
3.
Others
Item name
Description
Reference
System Condition
You can learn the connection availability as well as the version of the
GOT-F900 OS and the screen creation software.
9.1
System Configuration
You can select the configuration between the GOT and the A Series PLC/
computer link unit as well as proper cables.
9.2
Item name
Description
Reference
ACPU Selection in Direct
Connection
In the A computer link, the following setting is required.
When A connection is selected, the GOT-F900 is automatically set to
fixed values. No setting is required in the A Series PLC.
−
Setting in A Computer
Link Connection
You can learn the communication specifications and the setting.
9.3
Caution on Use of
MELSEC-A Series PLC
You can learn the restrictions in connecting the GOT to the A Series PLC.
9.4
Setting of Connected
Equipment for GOT
Set the PLC type using the GOT or the screen creation software.
9.5
Item name
Description
Reference
Cable Diagram
Cable diagrams for A Series PLC/GOT connection
9.6
Troubleshooting
Description of errors and how to fix them
9.7
Setting of A
computer link
The contents of setting of computer link
9.3.1
Setting of CD
signal control
The setting method in which CD signals are not
checked in the sequence program in RS-232C
connection
9.3.2
Setting
examples
Switch setting in each computer link
9.3.3
GOT-F900 SERIES (CONNECTION)
Summary of Contents for F920GOT-BBD-K-E
Page 4: ...GOT F900 SERIES CONNECTION ii ...
Page 6: ...GOT F900 SERIES CONNECTION iv ...
Page 38: ...GOT F900 SERIES CONNECTION Outline 2 2 10 MEMO ...
Page 70: ...GOT F900 SERIES CONNECTION Specifications 3 3 32 MEMO ...
Page 230: ...GOT F900 SERIES CONNECTION Connection of MELSEC F FX Series PLC 8 8 26 MEMO ...
Page 260: ...GOT F900 SERIES CONNECTION Connection of MELSEC A Series PLC 9 9 30 MEMO ...
Page 290: ...GOT F900 SERIES CONNECTION Connection of MELSEC QnA Series PLC 10 10 30 MEMO ...
Page 322: ...GOT F900 SERIES CONNECTION Connection of MELSEC Q Series PLC 11 11 32 MEMO ...
Page 376: ...GOT F900 SERIES CONNECTION Connection of FREQROL S500 E500 A500 Inverter 13 13 38 MEMO ...
Page 412: ...GOT F900 SERIES CONNECTION Connection of Microcomputer 14 14 36 MEMO ...
Page 554: ...GOT F900 SERIES CONNECTION Connection of Printer 21 21 8 MEMO ...
Page 590: ...GOT F900 SERIES CONNECTION Appendix 23 23 24 MEMO ...
Page 591: ......