GOT-F900 SERIES (CONNECTION)
Connection of SYSMAC C Series PLC (Manufactured by Omron) 15
15-14
15.6
Setting Examples in SYSMAC
αααα
(C200HE/HG/HX)/CPM 1A/2A/2C Series
When connecting the GOT-F900 to the SYSMAC
α
(C200HE/HG/HX) or CPM 1A/2A/2C Series, the data
shown below should be written to data memory (DM) using a peripheral tool.
This paragraph explains the contents of data memory (DM) to be set in each unit.
1) In the case of SYSMAC
αααα
Series (CPU equipped with built-in RS-232C port)
In the CPU C200HX-CPU44-Z, set the DIP switch shown below.
The table below explains the data memory (DM) Nos. and set values which should be set using a
peripheral tool.
2) In the case of SYSMAC
αααα
Series (serial communication board)
When connecting the GOT-F900 to the port 1 or the port 2 in the C200HW-COM06-V1, set the DIP
switch shown below.
The table below explains the data memory (DM) Nos. and set values which should be set using a
peripheral tool.
Setting item
Set value
Remarks
C200HX-CPU44-Z
DIP switch SW5
OFF
Setting item
Port
Set value (hexadecimal)
Remarks
Communication
DM6645
0001H
Communication condition: Set individually
(in accordance with setting of DM6646)
Host link mode
CTS control: Not provided
Transmission speed
DM6646
0304H
Baud rate: 19200 bps
Start bit length: 1 bit
Data length: 7 bits
Stop bit length: 2 bits
Parity: Even
Transmission delay time
DM6647
0000H
Transmission delay time: 0ms
Unit number
DM6648
0000 to 0031
Host link unit number (BCD value)
Setting item
Set value
Remarks
C200HW-COM06-V1
DIP switch SW1, 2
4-wire type
(without terminal resistor)
Refer to the description on the switches of
the C200HW-COM06-V1.
DIP switch SW1: 4
DIP switch SW2: OFF
Setting item
Set value
(hexadecimal)
Remarks
Setting item
Port B
Port A
Communication
DM6550 DM6555
0001H
Communication condition: Set individually
(in accordance with setting of next DM)
Host link mode
CTS control: Not provided
Transmission speed
DM6551 DM6556
0304H
Baud rate: 19200 bps
Start bit length: 1 bit
Data length: 7 bits
Stop bit length: 2 bits
Parity: Even
Transmission delay time
DM6552 DM6557
0000H
Transmission delay time: 0ms
Unit number
DM6553 DM6558
0000 to 0031
Host link unit number (BCD value)
Summary of Contents for F920GOT-BBD-K-E
Page 4: ...GOT F900 SERIES CONNECTION ii ...
Page 6: ...GOT F900 SERIES CONNECTION iv ...
Page 38: ...GOT F900 SERIES CONNECTION Outline 2 2 10 MEMO ...
Page 70: ...GOT F900 SERIES CONNECTION Specifications 3 3 32 MEMO ...
Page 230: ...GOT F900 SERIES CONNECTION Connection of MELSEC F FX Series PLC 8 8 26 MEMO ...
Page 260: ...GOT F900 SERIES CONNECTION Connection of MELSEC A Series PLC 9 9 30 MEMO ...
Page 290: ...GOT F900 SERIES CONNECTION Connection of MELSEC QnA Series PLC 10 10 30 MEMO ...
Page 322: ...GOT F900 SERIES CONNECTION Connection of MELSEC Q Series PLC 11 11 32 MEMO ...
Page 376: ...GOT F900 SERIES CONNECTION Connection of FREQROL S500 E500 A500 Inverter 13 13 38 MEMO ...
Page 412: ...GOT F900 SERIES CONNECTION Connection of Microcomputer 14 14 36 MEMO ...
Page 554: ...GOT F900 SERIES CONNECTION Connection of Printer 21 21 8 MEMO ...
Page 590: ...GOT F900 SERIES CONNECTION Appendix 23 23 24 MEMO ...
Page 591: ......