GOT-F900 SERIES (CONNECTION)
Connection of MELSEC-F FX Series PLC 8
8-9
1
In
tr
o
d
u
c
tio
n
2
Ou
tl
in
e
3
S
p
eci
fic
a
ti
on
s
4
in
st
a
ll
a
ti
o
n
an
d W
iri
ng
o
f
F9
40
G
O
T
5
in
s
ta
llat
io
n
an
d W
ir
in
g
of
Ha
n
d
y
GO
T
6
C
o
nne
c
ti
o
n o
f
P
e
ri
ph
er
al
Eq
ui
pm
en
t
7
C
o
nn
ect
io
n of
T
w
o or
Mor
e
GO
T
U
n
it
s
8
Co
n
n
e
c
ti
o
n
o
f
M
E
LSEC-
F
F
X
Se
ri
e
s
PLC
9
C
o
n
n
e
c
ti
on of
M
E
L
SEC-
A
Se
ri
e
s
PLC
10
C
onn
ec
ti
o
n
of
M
E
L
SEC-
Q
n
A
Se
ri
e
s
PLC
8.3.4
Restrictions in connecting two or more F920GOT-K (5V type) units to FX Series PLC
This section explains the restrictions in connecting two or more F920GOT-K units to the programming
port and the optional RS-422 expansion board (FX
"
N
-422-BD).
These restrictions are not imposed on the 24V type F920GOT-K.
When connecting to FX
1S
/FX
1N
PLC
- One F920GOT-K can be connected to one PLC.
- The display module (FX
1N
-5DM or FX-10DM) cannot be used concurrently.
When connecting to FX
2N
PLC
- Up to two units can be connected using the FX
2N
-422-BD.
Note, however, that the units are to be connected on the condition shown below (No special function
block can be used).
Unavailable combinations
The RS-422 expansion board cannot be used in the following combinations:
- FX
1S
, FX
1N
+ FX
1N
-5DM + FX
1N
-422-BD + F920GOT-K
- FX
1S
, FX
1N
+ F920GOT-K(or FX-10DM) + FX
1N
-422-BD + F920GOT-K(or FX-10DM)
- FX
2N
+
Special
function
block
+
F920GOT-K(or
FX-10DM)
+
FX
2N
-422-BD
+
F920GOT-K(or
FX-10DM)
F920GOT-K
(5V type)
or
FX-10DM
FX-10DM
or
F920GOT-K
(5V type)
Either one
FX
1S
,FX
1N
PLC
´ˆ ˜
˜
¯
˘
˙
ˆ¨
FX
1N
-422-BD
+
Example
F920GOT-K (5V type)
FX
1S
,FX
1N
PLC
FX
1N
-5DM
Example
FX
2N
PLC
FX
2N
-422-BD
=
Special function block
290mA
−
( Not to be c 220mA + 60mA ) = 10mA
A special function
block cannot be
used because
usable capacity is
less than 10mA.
5V power capacity
of PLC main unit
F920GOT-K
(5V type)
or
FX-10DM
Do not count F920GOT-K connected
to the inbuilt programming port of the
PLC when calculating 5V current
consumption.
5V current consumption
Capacity of 5V
power supply
Usable capacity
First
unit
Second
unit
Example
F920GOT-K
(5V type)
or
FX-10DM
−
No special
function block
can be used
Summary of Contents for F920GOT-BBD-K-E
Page 4: ...GOT F900 SERIES CONNECTION ii ...
Page 6: ...GOT F900 SERIES CONNECTION iv ...
Page 38: ...GOT F900 SERIES CONNECTION Outline 2 2 10 MEMO ...
Page 70: ...GOT F900 SERIES CONNECTION Specifications 3 3 32 MEMO ...
Page 230: ...GOT F900 SERIES CONNECTION Connection of MELSEC F FX Series PLC 8 8 26 MEMO ...
Page 260: ...GOT F900 SERIES CONNECTION Connection of MELSEC A Series PLC 9 9 30 MEMO ...
Page 290: ...GOT F900 SERIES CONNECTION Connection of MELSEC QnA Series PLC 10 10 30 MEMO ...
Page 322: ...GOT F900 SERIES CONNECTION Connection of MELSEC Q Series PLC 11 11 32 MEMO ...
Page 376: ...GOT F900 SERIES CONNECTION Connection of FREQROL S500 E500 A500 Inverter 13 13 38 MEMO ...
Page 412: ...GOT F900 SERIES CONNECTION Connection of Microcomputer 14 14 36 MEMO ...
Page 554: ...GOT F900 SERIES CONNECTION Connection of Printer 21 21 8 MEMO ...
Page 590: ...GOT F900 SERIES CONNECTION Appendix 23 23 24 MEMO ...
Page 591: ......