Restrictions in Number of Devices Monitored When Using FX-2PIF
The table below shows the applicable PLC according to the versions of FX-2PIF.
When using with an A Series PLC, there are restrictions in the quantity of data being monitored.
1) System Condition
-
The applicable dedicated equipment above can be connected to FX-2PIF.
2) Restrictions in the number of devices being monitored (only when the A Series PLC is
connected)
3) Calculation of active devices at one time (when the A Series PLC is connected)
The number of devices, "Number (Numerical Display), Bar Graph, Indicator (Lamp), Change Screen
(Display screen changeover)", in the USER SCREEN MODE is calculated using the following
formula. Have in mind, however, the number of devices being monitored varies depending on the
setting of the bar code reader, printer connection and GOT system in the screen creation software.
Common Base Overlap window 1 + Overlap window 2
≤
34
(Overlapped screens)
The total sum of devices from the Common screen (only in the DU/WIN software) and each of the
screens is calculated while referring to the table on the next page, and should be within the range
shown above. Correct monitoring cannot be executed if too many devices are connected.
Applicable PLC
Versions of FX-2PIF
Applicable dedicated equipment
FX Series
FX
0
, FX
0S
, FX
0N
, FX
1
, FX
2
, FX
2C
1.00 or later
FX-10P
FX-20P
GP-80
A6GPP/PHP
A7PHP/HGP
FX
2N
, FX
2NC
2.00 or later
A Series
AnA, AnN, A2C
2.00 or later
A1S, A0J2H
2.10 or later
AnU
2.20 or later
Two-port interface
ACPU direct connection
GOT-F900
GOT-F900
Dedicated equipment
GPP function
P/I
FX-2PIF
Maximum number of devices
that can be monitored in the
USER SCREEN MODE:
34 devices (objects) on the
currently displayed screen.
See below for the details.
Maximum number of devices
that can be monitored when
peripheral equipment for the
A Series PLC (a A6GPP or a
personal computer) is used:
103 devices
Summary of Contents for F920GOT-BBD-K-E
Page 4: ...GOT F900 SERIES CONNECTION ii ...
Page 6: ...GOT F900 SERIES CONNECTION iv ...
Page 38: ...GOT F900 SERIES CONNECTION Outline 2 2 10 MEMO ...
Page 70: ...GOT F900 SERIES CONNECTION Specifications 3 3 32 MEMO ...
Page 230: ...GOT F900 SERIES CONNECTION Connection of MELSEC F FX Series PLC 8 8 26 MEMO ...
Page 260: ...GOT F900 SERIES CONNECTION Connection of MELSEC A Series PLC 9 9 30 MEMO ...
Page 290: ...GOT F900 SERIES CONNECTION Connection of MELSEC QnA Series PLC 10 10 30 MEMO ...
Page 322: ...GOT F900 SERIES CONNECTION Connection of MELSEC Q Series PLC 11 11 32 MEMO ...
Page 376: ...GOT F900 SERIES CONNECTION Connection of FREQROL S500 E500 A500 Inverter 13 13 38 MEMO ...
Page 412: ...GOT F900 SERIES CONNECTION Connection of Microcomputer 14 14 36 MEMO ...
Page 554: ...GOT F900 SERIES CONNECTION Connection of Printer 21 21 8 MEMO ...
Page 590: ...GOT F900 SERIES CONNECTION Appendix 23 23 24 MEMO ...
Page 591: ......