GOT-F900 SERIES (CONNECTION)
Connection of MELSEC-Q Series PLC 11
11-12
11.4
Setting in Q Multi PLC System (Function version -B or later)
QCPU of function version -B or later (except Q00JCPU, Q00CPU, or Q01CPU) is compatible with the
multiple PLC system with 4 GOT units maximum.
If the OS version of the GOT-F900 and the screen creation software is compatible with Q multiple PLC
system, the screen creation software can specify the monitoring of other GOT through the connected
GOT and the CPU.
11.4.1
Direct connection to QCPU
The required setting and PLC numbers for connecting the GOT-F900 to the programming port of QCPU
(RS-232C) are shown below.
1) GOT-F900 connection
Each QCPU can be connected to the GOT-F900.
Connection of two or more GOT units can be performed and 2-port interface function (Program
transfer and monitor using GX Developer) is available.
2) Setting in the screen creation software
a) GT Designer2
- Select "Common"-"System Environment", then set "PLC Type" to "MELSEC-Q (Multi)".
- Click "Auxiliary Setting" in the "System Environment" tree, then give a check mark (
$
) to "Use
Serial Port, Setup, Language, Menu Key."
- Click "GOT Setup" in the "System Environment" tree. In "Connection", set "Port" to "RS-422" or
"RS-232C", "Type" to "CPU", and "Station No." to "0".
b) GT Designer
- Select MELSEC-Q (Multi) in the "GOT/PLC Type" dialog box.
- Specify RS-422 or RS-232C for Port, CPU for Type, and 0 for Station No. in the "Project Auxiliary
Setting" dialog box.
c) DU/WIN
- The setting is not available.
GX Developer
Multiple PLC system
Summary of Contents for F920GOT-BBD-K-E
Page 4: ...GOT F900 SERIES CONNECTION ii ...
Page 6: ...GOT F900 SERIES CONNECTION iv ...
Page 38: ...GOT F900 SERIES CONNECTION Outline 2 2 10 MEMO ...
Page 70: ...GOT F900 SERIES CONNECTION Specifications 3 3 32 MEMO ...
Page 230: ...GOT F900 SERIES CONNECTION Connection of MELSEC F FX Series PLC 8 8 26 MEMO ...
Page 260: ...GOT F900 SERIES CONNECTION Connection of MELSEC A Series PLC 9 9 30 MEMO ...
Page 290: ...GOT F900 SERIES CONNECTION Connection of MELSEC QnA Series PLC 10 10 30 MEMO ...
Page 322: ...GOT F900 SERIES CONNECTION Connection of MELSEC Q Series PLC 11 11 32 MEMO ...
Page 376: ...GOT F900 SERIES CONNECTION Connection of FREQROL S500 E500 A500 Inverter 13 13 38 MEMO ...
Page 412: ...GOT F900 SERIES CONNECTION Connection of Microcomputer 14 14 36 MEMO ...
Page 554: ...GOT F900 SERIES CONNECTION Connection of Printer 21 21 8 MEMO ...
Page 590: ...GOT F900 SERIES CONNECTION Appendix 23 23 24 MEMO ...
Page 591: ......