GOT-F900 SERIES (CONNECTION)
Installation and Wiring of Handy GOT 5
5-63
1
In
tr
o
d
u
c
tio
n
2
Ou
tl
in
e
3
S
p
eci
fic
a
ti
on
s
4
in
st
a
ll
a
ti
o
n
an
d W
iri
ng
o
f
F9
40
G
O
T
5
in
s
ta
llat
io
n
an
d W
ir
in
g
of
Ha
n
d
y
GO
T
6
C
o
nne
c
ti
o
n of
P
e
ri
ph
er
al
Eq
ui
pm
en
t
7
C
o
nn
ect
io
n o
f
T
w
o or
Mor
e
GO
T
U
n
it
s
8
C
o
nn
ec
ti
o
n
of
M
E
LSEC-
F
F
X
Se
ri
e
s
PLC
9
C
o
n
n
e
c
ti
on of
M
E
L
SEC-
A
Se
ri
e
s
PLC
10
C
o
n
n
e
c
ti
on
of
M
E
L
SEC-
Q
n
A
Se
ri
e
s
PLC
5.18.2
F940GOT Handy (F94*GOT-*BD-RH-E)
When an operation switch or emergency stop switch does not operate, check the following points.
•
Check whether external cables are connected correctly to the Handy GOT. (Refer to chapter 3)
•
While pressing and holding an operation switch or emergency stop switch, check the conduction
between wires (pins or terminal blocks) of the external cables and relay cable in the table below.
If no conduction is confirmed, wire breakage or poor contact may be present in the external cable or
relay cable, or the circuits inside the Handy GOT may be damaged.
If it is suspected that the circuits inside the Handy GOT are damaged, consult with a Mitsubishi
Electric distributor.
*1 Connect an external cable to the Handy GOT, press and hold each switch, then check the conduction
between pins or wires.
F9GT-HCAB-
"
M
37-pin D-sub, male connector
*2 Connect an external cable and relay cable to the Handy GOT, press and hold each switch, then check
the conduction between wires.
*3 Arrangement of color type.
Switch
name
Signals whose conductivity is checked
Signal
name
External cable
*1
External cable F9GT-HCAB-
!
M
+
Relay cable
*2
F9GT-HCAB2-150
F9GT-HCAB3-150
F9GT-HCAB5-150
F9GT-HCAB-3M
F9GT-HCAB-10M
SW1
SW-COM and SW1
12 and 13
White/Red and Gray/Blue (B)
*3
SW2
SW-COM and SW2
12 and 14
White/Red and Gray/Red (B)
*3
SW3
SW-COM and SW3
12 and 15
White/Red and Orange/Blue (B)
*3
SW3
SW-COM and SW4
12 and 16
White/Red and Orange/Red (B)
*3
ES1-1
ES1-1 and ES1-1
20 and 21
Pink/Red and Pink/Blue (D)
*3
ES1-2
ES1-2 and ES1-2
22 and 23
Orange/Red and Orange/Blue (D)
*3
KSW-1
KSW-COM and KSW-1
28 and 29
White/Blue and Yellow/Red (B)
*3
KSW-2
KSW-COM and KSW-2
28 and 30
White/Blue and Yellow/Blue (B)
*3
1
19
20
37
#
/
#
#
/
#
#
/
#
#
/
#
#
/
#
Arrangement of color (Color type)
Type A
Type B
Type C
Type D
Type E
Summary of Contents for F920GOT-BBD-K-E
Page 4: ...GOT F900 SERIES CONNECTION ii ...
Page 6: ...GOT F900 SERIES CONNECTION iv ...
Page 38: ...GOT F900 SERIES CONNECTION Outline 2 2 10 MEMO ...
Page 70: ...GOT F900 SERIES CONNECTION Specifications 3 3 32 MEMO ...
Page 230: ...GOT F900 SERIES CONNECTION Connection of MELSEC F FX Series PLC 8 8 26 MEMO ...
Page 260: ...GOT F900 SERIES CONNECTION Connection of MELSEC A Series PLC 9 9 30 MEMO ...
Page 290: ...GOT F900 SERIES CONNECTION Connection of MELSEC QnA Series PLC 10 10 30 MEMO ...
Page 322: ...GOT F900 SERIES CONNECTION Connection of MELSEC Q Series PLC 11 11 32 MEMO ...
Page 376: ...GOT F900 SERIES CONNECTION Connection of FREQROL S500 E500 A500 Inverter 13 13 38 MEMO ...
Page 412: ...GOT F900 SERIES CONNECTION Connection of Microcomputer 14 14 36 MEMO ...
Page 554: ...GOT F900 SERIES CONNECTION Connection of Printer 21 21 8 MEMO ...
Page 590: ...GOT F900 SERIES CONNECTION Appendix 23 23 24 MEMO ...
Page 591: ......