4.2
Configure line density measurement
The density measurement parameters control how density is measured and reported.
•
(Section 4.2.1)
•
(Section 4.2.2)
•
(Section 4.2.3)
•
Configure two‐phase flow parameters
(Section 4.2.4)
4.2.1
Configure
Density Measurement Unit
Display
OFF-LINE MAINT
>
OFF-LINE CONFG
>
UNITS
>
DENS
ProLink III
Device Tools
>
Configuration
>
Process Measurement
>
Line Density
>
Density Unit
Field Communicator
Configure
>
Manual Setup
>
Measurements
>
Density
>
Density Unit
Overview
Density Measurement Unit
controls the measurement units that will be used in density
calculations and reporting.
Restriction
If the API referral application is enabled, you cannot change the density measurement unit here. The
density measurement unit is controlled by the API table selection.
Procedure
Set
Density Measurement Unit
to the option you want to use.
The default setting for
Density Measurement Unit
is
g/cm3
(grams per cubic centimeter).
Related information
Set up the API referral application
Options for
Density Measurement Unit
The transmitter provides a standard set of measurement units for
Density Measurement Unit
.
Different communications tools may use different labels.
Options for
Density Measurement Unit
Table 4-1:
Unit description
Label
Display
ProLink III
Field Communicator
Specific gravity
(1)
SGU
SGU
SGU
Grams per cubic centimeter
G/CM3
g/cm3
g/Cucm
Grams per liter
G/L
g/l
g/L
Configure process measurement
Configuration and Use Manual
23
Summary of Contents for CDM100M
Page 8: ...Getting Started 2 Micro Motion Compact Density Meters CDM ...
Page 12: ...Before you begin 6 Micro Motion Compact Density Meters CDM ...
Page 20: ...Configuration and commissioning 14 Micro Motion Compact Density Meters CDM ...
Page 26: ...Introduction to configuration and commissioning 20 Micro Motion Compact Density Meters CDM ...
Page 110: ...Integrate the meter with the control system 104 Micro Motion Compact Density Meters CDM ...
Page 116: ...Operations maintenance and troubleshooting 110 Micro Motion Compact Density Meters CDM ...
Page 124: ...Transmitter operation 118 Micro Motion Compact Density Meters CDM ...
Page 194: ...Using the transmitter display 188 Micro Motion Compact Density Meters CDM ...
Page 208: ...Using ProLink III with the transmitter 202 Micro Motion Compact Density Meters CDM ...