Activate
Scroll
until the
EXIT
option is displayed, then activate
Select
.
•
If the
EXIT
option is not available, activate
Scroll
and
Select
simultaneously and
hold until the screen returns to the previous display.
6.
To exit the display menu system, you can use either of the following methods:
•
Exit each menu separately, working your way back to the top of the menu
system.
•
Wait until the display times out and returns to displaying process variable data.
B.3.1
Enter a floating-point value using the display
Certain configuration values (for example,
Lower Range Value
and
Upper Range Value
) are
entered as floating-point values. The display supports both decimal notation and
exponential notation for floating-point values.
The display allows you to enter a maximum of 8 characters, including the sign. The decimal
point is not counted as a character. Exponential notation is used to enter values that
require more than 8 characters.
Enter a floating-point value using decimal notation
Decimal notation allows you to enter values between –9999999 and 99999999. You can
use the decimal point to enter values with a precision of 0 through 4 (4 characters to the
right of the decimal point).
Decimal values entered via the display must meet the following requirements:
•
They can contain a maximum of 8 digits, or 7 digits plus a minus sign (
−
) to indicate
a negative number.
•
They can contain a decimal point. The decimal point does not count as a digit. The
decimal point must be positioned so that the precision of the value does not exceed
4.
When you first enter the configuration screen, the current configuration value is displayed
in decimal notation, and the active character is flashing. If the value is positive, no sign is
displayed. If the value is negative, a minus sign is displayed.
Procedure
•
To change the value:
1. Activate
Select
until the digit you want to change is active (flashing).
Select
moves the cursor one position to the left. From the leftmost position,
Select
moves the cursor to the rightmost digit.
2. Activate
Scroll
to change the value of the active digit.
3. Repeat until all digits are set as desired.
•
To change the sign of the value:
-
If the current value is negative, activate
Select
until the minus sign is flashing,
then activate
Scroll
until the space is blank.
Using the transmitter display
Configuration and Use Manual
173
Summary of Contents for CDM100M
Page 8: ...Getting Started 2 Micro Motion Compact Density Meters CDM ...
Page 12: ...Before you begin 6 Micro Motion Compact Density Meters CDM ...
Page 20: ...Configuration and commissioning 14 Micro Motion Compact Density Meters CDM ...
Page 26: ...Introduction to configuration and commissioning 20 Micro Motion Compact Density Meters CDM ...
Page 110: ...Integrate the meter with the control system 104 Micro Motion Compact Density Meters CDM ...
Page 116: ...Operations maintenance and troubleshooting 110 Micro Motion Compact Density Meters CDM ...
Page 124: ...Transmitter operation 118 Micro Motion Compact Density Meters CDM ...
Page 194: ...Using the transmitter display 188 Micro Motion Compact Density Meters CDM ...
Page 208: ...Using ProLink III with the transmitter 202 Micro Motion Compact Density Meters CDM ...