Options for
mA Output Process Variable
(continued)
Table 6-2:
Process variable
Label
Display
ProLink III
Field Communicator
Concentration measurement
Specific Gravity
SG
Specific Gravity
Specific Gravity (CM)
Concentration
CONC
Concentration
Concentration (CM)
Referred Density (Concen-
tration)
RDENS
Referred Density (Concen-
tration)
Density at Reference (CM)
6.2.2
Configure
Lower Range Value
(LRV) and
Upper Range Value
(URV)
Display
OFF-LINE MAINT
>
OFF-LINE CONFG
>
IO
>
CONFIG MAO 1
>
4 mA
OFF-LINE MAINT
>
OFF-LINE CONFG
>
IO
>
CONFIG MAO 1
>
20 mA
OFF-LINE MAINT
>
OFF-LINE CONFG
>
IO
>
CH B
>
MAO 2
>
CONFIG MAO 2
>
4 mA
OFF-LINE MAINT
>
OFF-LINE CONFG
>
IO
>
CH B
>
MAO 2
>
CONFIG MAO 2
>
20 mA
ProLink III
Device Tools
>
Configuration
>
I/O
>
Outputs
>
mA Output
>
mA Output 1
>
Lower Range Value
Device Tools
>
Configuration
>
I/O
>
Outputs
>
mA Output
>
mA Output 1
>
Upper Range Vaue
Device Tools
>
Configuration
>
I/O
>
Outputs
>
mA Output
>
mA Output 2
>
Lower Range Value
Device Tools
>
Configuration
>
I/O
>
Outputs
>
mA Output
>
mA Output 2
>
Upper Range Vaue
Field Communicator
Configure
>
Manual Setup
>
Inputs/Outputs
>
mA Output 1
>
mA Output Settings
>
PV LRV
Configure
>
Manual Setup
>
Inputs/Outputs
>
mA Output 1
>
mA Output Settings
>
PV URV
Configure
>
Manual Setup
>
Inputs/Outputs
>
mA Output 2
>
mA Output Settings
>
SV LRV
Configure
>
Manual Setup
>
Inputs/Outputs
>
mA Output 2
>
mA Output Settings
>
SV URV
Overview
The
Lower Range Value
(LRV) and
Upper Range Value
(URV) are used to scale the mA output,
that is, to define the relationship between
mA Output Process Variable
and the mA output
level.
Important
Your device may have been ordered with predefined values for
LRV
and
URV
that are appropriate for
specific applications. However, you can change these settings if you want to.
Prerequisites
Ensure that
mA Output Process Variable
is set to the desired process variable. Each process
variable has its own set of
LRV
and
URV
values. When you change the values of
LRV
and
URV
, you are configuring values for the currently assigned mA output process variable.
Integrate the meter with the control system
86
Micro Motion
®
Compact Density Meters (CDM)
Summary of Contents for CDM100M
Page 8: ...Getting Started 2 Micro Motion Compact Density Meters CDM ...
Page 12: ...Before you begin 6 Micro Motion Compact Density Meters CDM ...
Page 20: ...Configuration and commissioning 14 Micro Motion Compact Density Meters CDM ...
Page 26: ...Introduction to configuration and commissioning 20 Micro Motion Compact Density Meters CDM ...
Page 110: ...Integrate the meter with the control system 104 Micro Motion Compact Density Meters CDM ...
Page 116: ...Operations maintenance and troubleshooting 110 Micro Motion Compact Density Meters CDM ...
Page 124: ...Transmitter operation 118 Micro Motion Compact Density Meters CDM ...
Page 194: ...Using the transmitter display 188 Micro Motion Compact Density Meters CDM ...
Page 208: ...Using ProLink III with the transmitter 202 Micro Motion Compact Density Meters CDM ...