Procedure
Set
Flow Direction
to the value you want to use.
The default setting is
Forward
.
Options for
Flow Direction
Options for
Flow Direction
Table 4-5:
Flow Direction
setting
Relationship to Flow Direction arrow on
sensor
Effect on velocity measure-
ment
ProLink III
Field Communica-
tor
Forward
Forward
Appropriate when the Flow Direction ar-
row is in the same direction as the majori-
ty of flow.
No effect
Reverse
Reverse
Appropriate when the Flow Direction ar-
row is in the opposite direction from the
majority of flow.
No effect
Absolute Value
Absolute Value
Flow Direction arrow is not relevant.
The absolute value of the proc-
ess variable is used.
Bidirectional
Bi directional
Appropriate when both forward and re-
verse flow are expected, and forward flow
will dominate, but the amount of reverse
flow will be significant.
No effect
Negate Forward
Negate/Forward Only
Appropriate when the Flow Direction ar-
row is in the opposite direction from the
majority of flow.
The sign of the process variable
is reversed.
Negate Bidirectional
Negate/Bi-directional
Appropriate when both forward and re-
verse flow are expected, and reverse flow
will dominate, but the amount of forward
flow will be significant.
The sign of the process variable
is reversed.
Effect of
Flow Direction
on mA outputs
Flow Direction
affects how the transmitter reports velocity via the mA outputs. The mA
outputs are affected by
Flow Direction
only if
mA Output Process Variable
is set to
Velocity
.
Flow Direction
and mA outputs
The effect of
Flow Direction
on the mA outputs depends on
Lower Range Value
configured for
the mA output:
•
If
Lower Range Value
is set to 0, see
•
If
Lower Range Value
is set to a negative value, see
.
Configure process measurement
40
Micro Motion
®
Compact Density Meters (CDM)
Summary of Contents for CDM100M
Page 8: ...Getting Started 2 Micro Motion Compact Density Meters CDM ...
Page 12: ...Before you begin 6 Micro Motion Compact Density Meters CDM ...
Page 20: ...Configuration and commissioning 14 Micro Motion Compact Density Meters CDM ...
Page 26: ...Introduction to configuration and commissioning 20 Micro Motion Compact Density Meters CDM ...
Page 110: ...Integrate the meter with the control system 104 Micro Motion Compact Density Meters CDM ...
Page 116: ...Operations maintenance and troubleshooting 110 Micro Motion Compact Density Meters CDM ...
Page 124: ...Transmitter operation 118 Micro Motion Compact Density Meters CDM ...
Page 194: ...Using the transmitter display 188 Micro Motion Compact Density Meters CDM ...
Page 208: ...Using ProLink III with the transmitter 202 Micro Motion Compact Density Meters CDM ...