![Lenovo System x3650 M4 HD Installation And Service Manual Download Page 55](http://html.mh-extra.com/html/lenovo/system-x3650-m4-hd/system-x3650-m4-hd_installation-and-service-manual_202669055.webp)
0000
0000
0000
0000
0000
000
000
000
000
1.8-inch
hot-swap
hard disk drive
Filler
Figure 30. 1.8-inch hot-swap solid state drives installation
b.
Push the drive tray into the drive bay and rotate the drive tray handle to the closed position
and ensure that the latch is in the locked position.
c.
Reinstall the filler panel.
Step 6.
Check the hard disk drive status LED to verify that the hard disk drive is operating correctly. If
the yellow hard disk drive status LED of a drive is lit continuously, that drive is faulty and must be
replaced. If the green hard disk drive activity LED is flashing, the drive is being accessed.
Note:
If the server is configured for RAID operation using a ServeRAID adapter, you might have
to reconfigure your disk arrays after you install hard disk drives. See the ServeRAID adapter
documentation for additional information about RAID operation and complete instructions for
using the ServeRAID adapter.
If you have other devices to install or remove, do so now. Otherwise, go to “Completing the installation”
on page 94.
Installing a memory module
The following notes describe the types of DIMMs that the server supports and other information that you
must consider when you install DIMMs.
• When you install or remove DIMMs, the server configuration information changes. When you restart the
server, the system displays a message that indicates that the memory configuration has changed.
• The server supports only industry-standard double-data-rate 3 (DDR3), 800, 1066, 1333, 1600, or
1866 MHz, PC3-6400, PC3-8500, PC3-10600, PC3-12800, or PC3-14900 registered or unbuffered,
synchronous dynamic random-access memory (SDRAM) dual inline memory modules (DIMMs) with
error correcting code (ECC). See http://www.lenovo.com/ serverproven/ for a list of supported memory
modules for the server.
– The specifications of a DDR3 DIMM are on a label on the DIMM, in the following format.
gggggeRxff
PC3
v
-
wwwwwm
-
aa
-
bb
-
ccd
where:
–
ggggg
is the total capacity of the DIMM (for example, 1 GB, 2 GB, or 4 GB)
–
eR
is the number of ranks
1R = single-rank
43
Summary of Contents for System x3650 M4 HD
Page 1: ...Lenovo System x3650 M4 HD Installation and Service Guide Machine Type 5460 ...
Page 6: ...iv Lenovo System x3650 M4 HD Installation and Service Guide ...
Page 134: ...122 Lenovo System x3650 M4 HD Installation and Service Guide ...
Page 178: ...166 Lenovo System x3650 M4 HD Installation and Service Guide ...
Page 190: ...178 Lenovo System x3650 M4 HD Installation and Service Guide ...
Page 314: ...302 Lenovo System x3650 M4 HD Installation and Service Guide ...
Page 964: ...952 Lenovo System x3650 M4 HD Installation and Service Guide ...
Page 988: ...976 Lenovo System x3650 M4 HD Installation and Service Guide ...
Page 1146: ...1134 Lenovo System x3650 M4 HD Installation and Service Guide ...
Page 1150: ...1138 Lenovo System x3650 M4 HD Installation and Service Guide ...
Page 1158: ...Taiwan BSMI RoHS declaration 1146 Lenovo System x3650 M4 HD Installation and Service Guide ...
Page 1167: ......
Page 1168: ......