• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
• Go to the Lenovo support website at http://www.lenovo.com/support to check for technical information,
hints, tips, and new device drivers or to submit a request for information.
Symptom
Action
If an optional embedded
hypervisor flash device is not
listed in the expected boot
order, does not appear in the
list of boot devices, or a similar
problem has occurred.
1. Make sure that the optional embedded hypervisor flash device is selected on
the boot manager
<F12> Select Boot Device
at startup.
2. Make sure that the embedded hypervisor flash device is seated in the connector
correctly (see “Removing the USB flash drive” on page 197 and “Installing
the USB flash drive” on page 198).
3. See the documentation that comes with the optional embedded hypervisor
flash device for setup and configuration information.
4. Make sure that other software works on the server.
Intermittent problems
Use this information to solve intermittent problems.
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
• Go to the Lenovo support website at http://www.lenovo.com/support to check for technical information,
hints, tips, and new device drivers or to submit a request for information.
Symptom
Action
A problem occurs only
occasionally and is difficult to
diagnose.
1. Make sure that:
• All cables and cords are connected securely to the rear of the server and
attached devices.
• When the server is turned on, air is flowing from the fan grille. If there is
no airflow, the fan is not working. This can cause the server to overheat
and shut down.
2. Check the system-error log or IMM event logs (see “Event logs” on page 58).
The server resets (restarts)
occasionally.
1. If the reset occurs during POST and the POST watchdog timer is enabled (click
System Settings
➙
Recovery
➙
System Recovery
➙
POST Watchdog Timer
in the Setup utility to see the POST watchdog setting), make sure that sufficient
time is allowed in the watchdog timeout value (
POST Watchdog Timer
). If the
server continues to reset during POST, see Appendix B “UEFI (POST) error
codes” on page 805 and “Lenovo Dynamic System Analysis” on page 60.
2. If neither condition applies, check the system-error log or IMM system-event
log (see “Event logs” on page 58).
Keyboard, mouse, or USB-device problems
Use this information to solve keyboard, mouse, or USB-device problems.
65
Summary of Contents for NeXtScale nx360 M5
Page 1: ...Lenovo NeXtScale nx360 M5 Installation and Service Guide Machine Type 5465 ...
Page 42: ...28 Lenovo NeXtScale nx360 M5 Installation and Service Guide ...
Page 98: ...84 Lenovo NeXtScale nx360 M5 Installation and Service Guide ...
Page 114: ...100 Lenovo NeXtScale nx360 M5 Installation and Service Guide ...
Page 242: ...228 Lenovo NeXtScale nx360 M5 Installation and Service Guide ...
Page 818: ...804 Lenovo NeXtScale nx360 M5 Installation and Service Guide ...
Page 1002: ...988 Lenovo NeXtScale nx360 M5 Installation and Service Guide ...
Page 1009: ...Taiwan Class A compliance statement Appendix E Notices 995 ...
Page 1010: ...Taiwan BSMI RoHS declaration 996 Lenovo NeXtScale nx360 M5 Installation and Service Guide ...
Page 1012: ...998 Lenovo NeXtScale nx360 M5 Installation and Service Guide ...
Page 1020: ...1006 Lenovo NeXtScale nx360 M5 Installation and Service Guide ...
Page 1021: ......
Page 1022: ...Part Number 00MV789 Printed in China 1P P N 00MV789 1P00MV789 ...