1. Read “Safety” on page v and “Installation guidelines” on page 101.
2. If the compute node is installed in a NeXtScale n1200 Enclosure, remove it (see “Removing a compute
node from a chassis” on page 104 for instructions).
3. Carefully lay the compute node on a flat, static-protective surface, orienting the compute node with
the bezel pointing toward you.
To remove the PCI riser filler, complete the following steps:
Step 1.
Remove the cover (see “Removing the compute node cover” on page 113).
Step 2.
Grasp the PCI riser filler and lift the PCI riser filler up.
00
0000
0000
0000
0
000000
000000
000000
Figure 32. PCI riser filler removal
Step 3.
Remove the PCI riser filler from the compute node and set it aside.
Attention:
For proper cooling and airflow, replace the PCI riser filler before you turn on the
compute node. Operating the compute node with the PCI riser filler removed might damage
compute node components.
Replacing the PCI riser filler
Use this information to install the PCI riser filler.
Before you install the PCI riser filler, complete the following steps:
1. Read “Safety” on page v and “Installation guidelines” on page 101.
2. If the compute node is installed in a NeXtScale n1200 Enclosure, remove it (see “Removing a compute
node from a chassis” on page 104 for instructions).
3. Carefully lay the compute node on a flat, static-protective surface, orienting the compute node with
the bezel pointing toward you.
To install the PCI riser filler, complete the following steps:
Step 1.
Remove the cover (see “Removing the compute node cover” on page 113).
Step 2.
Align the PCI riser filler pin with the baffle pin hole on the right side of the chassis; then, lower the
PCI riser filler into the compute node. Press the PCI riser filler down until it is securely seated.
Removing and replacing components
119
Summary of Contents for NeXtScale nx360 M5
Page 1: ...Lenovo NeXtScale nx360 M5 Installation and Service Guide Machine Type 5465 ...
Page 42: ...28 Lenovo NeXtScale nx360 M5 Installation and Service Guide ...
Page 98: ...84 Lenovo NeXtScale nx360 M5 Installation and Service Guide ...
Page 114: ...100 Lenovo NeXtScale nx360 M5 Installation and Service Guide ...
Page 242: ...228 Lenovo NeXtScale nx360 M5 Installation and Service Guide ...
Page 818: ...804 Lenovo NeXtScale nx360 M5 Installation and Service Guide ...
Page 1002: ...988 Lenovo NeXtScale nx360 M5 Installation and Service Guide ...
Page 1009: ...Taiwan Class A compliance statement Appendix E Notices 995 ...
Page 1010: ...Taiwan BSMI RoHS declaration 996 Lenovo NeXtScale nx360 M5 Installation and Service Guide ...
Page 1012: ...998 Lenovo NeXtScale nx360 M5 Installation and Service Guide ...
Page 1020: ...1006 Lenovo NeXtScale nx360 M5 Installation and Service Guide ...
Page 1021: ......
Page 1022: ...Part Number 00MV789 Printed in China 1P P N 00MV789 1P00MV789 ...