Step 3.
Install the SAS/SATA adapter to the riser cage and close the retention bracket. It will secure the
SAS/SATA adapter in place when the adapter is firmly seated into the connector.
3
RAID adapter
Riser card assembly
Figure 133. RAID adapter installation
Step 4.
Route the backplane signal cables (see “Cabling hard disk drive with ServeRAID SAS/SATA
controller” on page 218).
Step 5.
Connect the signal cables to the SAS/SATA adapter:
Step 6.
Align the riser card golden finger with the planar RAID PCI slot.
Step 7.
Insert the adapter riser cage into the RAID connector until it is firmly seated.
Attention:
Incomplete insertion might cause damage to the server or the adapter.
Figure 134. ServeRAID adapter installation
Note:
Remove the PCI bracket that comes with ServeRAID N2215 adapter before installing it in
the dedicated connector on the system board.
Step 8.
Reconnect any cables that you removed.
196
Lenovo NeXtScale nx360 M5 Installation and Service Guide
Summary of Contents for NeXtScale nx360 M5
Page 1: ...Lenovo NeXtScale nx360 M5 Installation and Service Guide Machine Type 5465 ...
Page 42: ...28 Lenovo NeXtScale nx360 M5 Installation and Service Guide ...
Page 98: ...84 Lenovo NeXtScale nx360 M5 Installation and Service Guide ...
Page 114: ...100 Lenovo NeXtScale nx360 M5 Installation and Service Guide ...
Page 242: ...228 Lenovo NeXtScale nx360 M5 Installation and Service Guide ...
Page 818: ...804 Lenovo NeXtScale nx360 M5 Installation and Service Guide ...
Page 1002: ...988 Lenovo NeXtScale nx360 M5 Installation and Service Guide ...
Page 1009: ...Taiwan Class A compliance statement Appendix E Notices 995 ...
Page 1010: ...Taiwan BSMI RoHS declaration 996 Lenovo NeXtScale nx360 M5 Installation and Service Guide ...
Page 1012: ...998 Lenovo NeXtScale nx360 M5 Installation and Service Guide ...
Page 1020: ...1006 Lenovo NeXtScale nx360 M5 Installation and Service Guide ...
Page 1021: ......
Page 1022: ...Part Number 00MV789 Printed in China 1P P N 00MV789 1P00MV789 ...