281
Reset-Synchronized PWM Mode: The BR value is transferred to GR upon a GRA3 compare
match.
Procedure for Selecting Buffer Mode (Figure 10.47):
1. Set TIOR to select the output compare or input capture function of GR.
2. Set bits BFA3, BFB3 and BFB4 in TFCR to select buffer mode for GR.
3. Set the STR bit in TSTR to 1 to start the TCNT count.
(1)
(2)
(3)
Select general register function
Buffer mode
Select buffer mode
Start counting
Buffer mode
Figure 10.47 Procedure for Selecting Buffer Mode
Buffer Mode Operation: Figure 10.48 shows an example of an operation in buffer mode with
GRA set as an output compare register and GRA and buffer register A (BRA) set for buffer
operation. TCNT operates as a periodic counter that is cleared by a GRB compare match. TIOCA
and TIOCB are set to toggle at compare matches A and B. Since buffer mode is selected, when
TIOCA toggles at compare match A, the BRA value is simultaneously transferred to GRA. This
operation is repeated at every compare match A. The transfer timing is shown in figure 10.49.
Summary of Contents for HD6417032
Page 21: ......
Page 35: ...xiv ...
Page 85: ...50 ...
Page 101: ...66 ...
Page 129: ...94 ...
Page 135: ...100 ...
Page 343: ...308 ...
Page 369: ...334 ...
Page 383: ...348 ...
Page 475: ...440 ...
Page 525: ...490 CK RAS CAS TRp TRc TRcc tRASD1 tRASD2 tCASD3 tCASD2 TRr tCSR Figure 20 18 Self Refresh ...
Page 578: ...543 CK RAS CAS TRp TRc TRcc tRASD1 tRASD2 tCASD3 tCASD2 TRr tCSR Figure 20 62 Self Refresh ...
Page 689: ...654 ...