276
GR Setting in Complementary PWM Mode: Note the following when setting the general
registers in complementary PWM mode and when making changes during operation.
•
Initial values: Settings from H'0000 to T–1 (T: TCNT3 initial setting) are prohibited. After
counting starts, this setting is allowed from the point when the first A3 compare match occurs.
•
Methods of changing settings: Use buffer operation. Writing directly to general registers may
result in incorrect waveform output.
•
When changing settings: See figure 10.38.
GRA3
GR
H' 0000
BR
GR
Prohibited
Figure 10.38 Example of Changing GR Settings with Buffer Operation (1)
Buffer Transfers when Changing from Increment to Decrement: When the contents of GR are
in the range GRA3 – T + 1 to GRA3, do not transfer a value outside this range. When the contents
of GR are outside this range, do not a transfer a value within it. Figure 10.39 illustrates a point for
caution regarding changing of GR settings with buffer operation.
GRA3 + 1
GRA3
GRA3 – T + 1
GRA3 – T
TCNT3
TCNT4
Changes prohibited
Figure 10.39 Caution on Changing GR Settings with Buffer Operation (1)
Buffer Transfers when Changing from Decrement to Increment: When the contents of GR are
in the range H'0000 to T–1, do not transfer a value outside this range. When the contents of GR
are outside this range, do not transfer a value within it. Figure 10.40 illustrates this point for
caution regarding changing of GR settings with buffer operation
Summary of Contents for HD6417032
Page 21: ......
Page 35: ...xiv ...
Page 85: ...50 ...
Page 101: ...66 ...
Page 129: ...94 ...
Page 135: ...100 ...
Page 343: ...308 ...
Page 369: ...334 ...
Page 383: ...348 ...
Page 475: ...440 ...
Page 525: ...490 CK RAS CAS TRp TRc TRcc tRASD1 tRASD2 tCASD3 tCASD2 TRr tCSR Figure 20 18 Self Refresh ...
Page 578: ...543 CK RAS CAS TRp TRc TRcc tRASD1 tRASD2 tCASD3 tCASD2 TRr tCSR Figure 20 62 Self Refresh ...
Page 689: ...654 ...