The Installer Menu
i-on Range
Page 34
Part Set Siren Delay
0 minutes
For part set.
Part Set Siren Time
15 minutes
For part set.
To comply with EN50131-1
Clause 8.6 minimum is 90s,
maximum is 15mins.
Part Set Final Exit
Final exit
Part Set Entry Route
Entry Route
Part Set Strobe Set
Off
Part Set Strobe Unset
Off
Partition 2...20 (i-on160)
Partition 2...4 (i-on30)
―Partition nn‖
Number of partitions depends
on panel type. All other
defaults as for Partition 1.
Full Set Link
Partitions 2-nn: No
30 40 50 160.
Number
of partitions depends on panel
type. Partition 1 is common
partition.
Calendar Set
None
50 160
No events or partitions
4 SYSTEM OPTIONS
Wired Zone type
30 40 50 160
Select the global wiring type
during initial power up.
Panel Zones
2 Wire FSL 2k2/4k7
All Zones
2 Wire FSL 2k2/4k7
30 50 160
User Access
HUA keys active
No
Quick Set
No
This setting is required in
order to comply with
EN50131.
Quick Omit
No
User code req
’d
Yes
This setting is required in
order to comply with
EN50131.
2 Way Replies
Yes
Used with FOB-2W-4B
Duress Enable
No
(Change to Yes for Duress
Code.)
User reset
Zone alarms
Yes
This option appears only if
Confirmation Mode is ”Basic”
Zone tampers
Grade 2: Yes
Grade 3: No
For INCERT approval set to
NO.
System tampers
No
Confirmation
Confirmation Mode
DD243
Not available for EUR
versions.
BS8243
Default for UK systems.
Not available for EUR
versions.
Basic
Default for EUR systems.
Confirmation time
30 minutes
Visible for DD243 or BS8243.
Can be adjusted between 1
and 60 minutes. Note that
only values of 30 minutes or
more comply with DD243 or
BS8243.