i-on Range
The System Bus
Page 23
Figure 5. Detector Connection Point Addressing.
Output Numbering
Output numbering is an extension of the way that devices are addressed on
the bus. Each output has a connection point address. The address contains
three groups of digits:
An>dd>oo
An>dd The first two groups are the address of the bus device (see page 21).
The ―A‖ can be a ―P‖ for the panel, ―W‖ for a wired expander or ―R‖ for
a radio expander.
>
The ―>‖ character is a reminder that the address is a output.
oo =
The last group is the output number.
Outputs connected directly to the control unit are numbered P0>00>01 to
P0>00>04 (P0>00>01 only on i-on30EX). See Figure 6 for examples:
Figure 6. Output Numbering.