i-on Range
Installer Menu Options
Page 107
on which the call should take place. Next, key in the hour of the day (01 to 24)
on which the test call should occur..
To make test calls on one day every month select
Communications – ARC
Reporting – Static Test Call – Monthly.
From the display select a number between
1 and 31 to specify the day of the month on which the call should take place.
Next, key in the hour of the day (01 to 24) on which the test call should occur.
For each of the three types of call, the control unit will add or subtract up to 16
minutes at random to the hour you specified. This is to make sure that the ARC
is not overwhelmed with a flood of test calls from systems that have all been
given the same time.
Select
Communications – ARC Reporting – Static Test Call – Disabled
to disable
static test calls.
Unset Comms
Use this option to prevent the system sending excessive communications
traffic while the system is unset.
Enabled
The control unit communicates all signals regardless of whether
the system is set or unset.
Disabled
The control unit sends tampers, mains fail and other status signals
when the system is set, but not when it is unset.
Speech Dialler
The i-sd01 (for i-on16), i-sd02 and i-gsm02 have a built-in speech dialler.
These modules can record five speech messages using their internal
microphones and replay them to a pre-programmed telephone number to
report an alarm. One message is called the ―Home message‖, and is always
played at the beginning of a report. You should use this message to identify
the control unit and it‘s location. The other four messages allow you to record
some indication of the type of event causing an alarm, for example: ―Fire‖ or
―Hold Up Alarm‖. The control unit plays these messages after the home
message.
While programming the speech diallers you link each message with the specific
alarm type you wish to report. You then select a set of destinations for each
message, where each destination corresponds to one of the telephone numbers
you wish to call (see Figure 10).
Summary of Contents for i-On 40
Page 1: ......
Page 10: ...i on Range Page x This page is intentionally blank...