i-on Range
The Installer Menu
Page 33
Part Set B
Name
―Part Set B‖
Exit Mode
Instant Set
Settle time
10seconds
Appears only if Exit Mode is
―Final Door‖, ―Lock Set‖ or
―Exit Terminate‖.
Exit time
40seconds
Appears only if Exit Mode is
―Timed Exit‖ or ―Silent Set‖.
Entry time
40seconds
The maximum time permitted
by EN50131-1 Clause 8.3 is
45 seconds.
Alarm Response
Siren
Includes Internal Alarm
Siren Delay
0 minutes
Siren Time
15 minutes
To comply with EN50131-1
Clause 8.6 minimum is 90s,
maximum is 15mins.
Part Set Final Exit
Final exit
Part Set Entry Route
Entry Route
Strobe on Set
Off
This setting is required in
order to comply with
EN50131.
Strobe on Unset
Off
Part C, D
(See Part Set B)
Calendar Set
None
50 160
3 PARTITIONS
30 40 50 160
Appears only in a Partitioned
system.
Partition 1
Name
―Partition 1‖
Exit Mode
Timed Set
Settle Time
10seconds
Appears only if Exit Mode is
―Final Door‖.
Exit Time
40seconds
Appears only if Exit Mode is
―Timed Exit‖ or ―Silent Set‖.
Entry Time
40seconds
The maximum time permitted
by EN50131-1 Clause 8.3 is
45 seconds.
Alarm Response
Siren + Comms
HUA Response
Audible
Appears here for partitioned
systems. Applies to both full
and part set partition.
Siren Delay
0 minutes
For full set only.
Siren Time
15 minutes
For full set only.
To comply with EN50131-1
Clause 8.6 minimum is 90s,
maximum is 15mins.
Strobe on Set
Off
Strobe on Unset
Off
Part Set Exit Mode
Instant Set
Part Set Settle Time
10 seconds
Appears only if Exit Mode is
―Final Door‖.
Part Set Exit Time
40 seconds
Appears only if Exit Mode is
―Timed Set‖ or ―Silent Set‖.
Part Set Entry Time
40seconds
Part Set Alarm
Response
Siren
Includes Internal alarm.
This setting is required in
order to comply with
EN50131.