Installer Menu Options
i-on Range
Page 94
Be aware that if you choose the Tamper option and also
System Options – User
Reset – Tampers
= ―No‖ then the user will not be able to reset the system after
a loss of supervision event.
Jamming
The control unit can detect interfering (or "jamming") radio signals. To enable
jamming detection select
System Options
-
Jamming
.
The options available for this alarm are:
Option:
With system SET, the
control unit:
With system UNSET the
control unit:
Off
Does nothing.
Does nothing.
Fault
Logs the event (but does NOT
display any alert or fault
tone).
Displays an Alert and sounds a
fault tone and logs the event.
Tamper
Starts a Tamper alarm and
notifies the ARC with a
―Jamming‖ message.
Starts a Tamper alarm and
notifies the ARC with a
―Jamming‖ message.
Note: The Tamper option is required for PD 6662:2010.
Be aware that if you choose the Tamper option and also
System Options – User
Reset – Tampers
= ―No‖ then the user will not be able to reset the system after
a Jamming event.
Force Set
You may wish to allow a user with a remote control to set the alarm system
when one or more of the detectors are not working or are open (active).
Note: If you enable “Force Set” then the system does not comply with
EN50131.
There are three options available:
Off
The remote control user cannot force set the system, even if you have
applied the force set zone attribute to any zones.
Confirm
The remote control user can force set the system. They must operate as
follows: 1) the user presses the appropriate button to set the system, 2)
the control unit does not start setting, 3) the user presses the same
remote control button to confirm that they wish to continue setting the
system.
On
The user need only press the remote control button once to complete
setting the system.
Note: The Confirm and On options will also allow a user with a remote control
to set the system if a reset is required after an alarm.
If any user is attempting to reset the system from a wired keypad when a
remote user tries to set the system, then the control unit will temporarily
ignore the remote user.
Summary of Contents for i-On 40