i-on Range
Introduction
Page 3
Relay Outputs
40
50 160.
The i-on40, i-on50EX and i-on160EX control unit also provide sets of
connectors for relay outputs, providing voltage free changeover contacts. Relay
outputs are programmable by the Installer.
See page 8 for the number of relay outputs available on each control unit.
Digital Communicator Outputs (Plug-by Outputs)
30 40
50 160.
A set of pins on the control unit PCB provide programmable outputs designed
to control a separate digital communicator.
By default each output is switched negative (switched from +12V to 0V when
active). When at 0V each communicator output can sink up to 100mA.
The installer can program these outputs to be switched positive when active
(switched from 0V to +12V). When at +12V each output can provide up to
50mA to an external load.
See page 8 for the number of relay outputs available on each control unit.
USB Port
30 40
50 160.
The USB port allows an Installer to program the control unit through a USB
cable from a PC to the control unit. The PC must be running Cooper Security‘s
i-on Downloader.
The USB port also allows an Installer to apply software updates to the control
unit or, in European versions, install alternate language text files for the
keypad display. To do this the Installer must run Cooper Security‘s i-on
Updater software on the connected PC.
The Downloader and i-on Updater software is available to registered users
from the Touchpoint pages on www.coopersecurity.co.uk.
Ethernet Port
40
50 160.
The Ethernet port also allows a local connection to a PC. The Ethernet
connection is designed to allow an Installer to program the control unit through
a series of web pages presented by a built-in web server running on the
control unit. Cooper Security recommend that you use Internet Explorer 8 or
higher to browse the pages.
External Bell/Strobe Outputs
30 50 160.
The control unit has one external bell output to drive standard Self-Activating
Bell (SAB) or Self-Contained Bell (SCB) modules, and one output to activate a
strobe. Expanders also provide connectors for additional external sounders.
See the
Installation Guide
for each product for details of maximum current
available for external bells.
Summary of Contents for i-On 40
Page 1: ......