Installer Menu Options
i-on Range
Page 74
Settle Time
This option allows you to define a time delay to allow detectors to settle
before the system sets. This may be needed if detectors are being set off
by air movements caused by the final door being closed. During this
period, the sounders stop and the system sets but the control unit ignores
any alarms generated by the detectors.
Enter two digits to specify a time in seconds, from 01 to 30.
Note: This option is available for Final Door Set. Lock Set and Exit Terminate
exit modes only.
Exit Time
The exit time can take any value between 10s and 120s.
Note: This option is available for Timed Set and Silent Set exit modes only.
Entry Time
The entry time can take any value between 10s and 120s. The entry time
you select in this option applies to Full set and all Part Sets.
Strobe on Set (Part Set Strobe Set)
When set to ON this option causes the control unit to activate any output
programmed as Strobe, plus the strobe on any 760ES wireless siren. The
outputs/strobes are active for three seconds after the system sets. Strobe
On Set applies to Full Set and all the Part Sets.
Strobe on Unset (Part Set Strobe on Set)
When set to ON this option causes the control unit to activate any output
programmed as Strobe, plus the strobe on any 760ES wireless siren. The
outputs/strobes are active for three seconds after the system unsets.
Strobe On Unset applies to Full Set and all the Part Sets.
Alarm Response/Part Set Alarm Response
You can select one of the following:
Internal:
Keypads and loudspeakers.
Siren
Keypads, loudspeakers and siren.
Siren + Comms
Keypads, loudspeakers, siren and
communication. Note that any Siren
Delay (see page 75) applies to
―Siren+Comms‖, but not ―Internal‖ or
―Siren‖ alarm responses.
HUA Response
During a HUA alarm the control unit starts communications (provided you have
a communication module fitted and enabled, or the communications outputs
wired to an appropriate communicator and correctly programmed). This option
controls the associated audible alarm.
Audible
As well as starting communications the control unit starts
HUA alarm tones from the keypads and loudspeakers, and
activates any siren outputs. The sirens follow the Siren
Time (see page 75). The loudspeakers operate until a user
silences the alarm.
Silent
The control unit keeps the HUA alarm silent: there are no
alarm tones from keypads or loudspeakers and any siren