Protocol
This option allows you to select the protocol used by
the Service Centre. The options available are: TAP 8N1,
TAP 7E1 , UCP 8N1 and UCP 7E1.
Service Centre Tel No The option allows you to store the Service Centre‘s
telephone number. Consult the technical support
department of the service provider that you wish to
use. When asking for the service centre number ask
which protocol they support. Press * to insert a two
second pause, if required. The display shows this as a
comma.
Line Fail Response
This menu lets you program the system to respond with either audible or silent
alarms when the control unit detects a fault on one of its communication lines.
To program Line Fail Response select
Communications – Line Fail Response
.
The exact response depends on whether the system is set or unset, as follows:
Audible
If the system is unset then the system logs the event.
The keypads produce a short audible tone every
minute. Entering a valid access code silences the
sounders and the display indicates a telephone line
fault. The system can be set again with the line fault
present.
If the system is set then the control unit logs the event
but does not give any tone or display. The control unit
cancels any programmed siren delay if the line is out of
order when an alarm occurs.
Note: Cooper Security recommend audible response for line fault.
Silent
If the system is unset then the display indicates a
telephone line fault and the control unit logs the event.
The system may be set again with the line fault
present.
If the system is set then the control unit does not give
any indication or tone but does log the event. The
control unit cancels any programmed siren delay if the
line is out of order when an alarm occurs.
Disabled
The control unit does not monitor the telephone line.
Line Fail Delay
This menu controls the length of time that the control unit waits until starting
an alert if the communications line fails. The values available are 0 to 60
seconds.
Note: The control unit may take a few seconds to recognise a line fail. The
actual delay between line fail and the resulting alert will slightly longer
than the value you program within this option.