i-on Range
Page 130
Step By Step Programming Procedures
The detailed procedures shown in this section are here to help those who are
not familiar with the Installer Menu. The procedures do not cover the whole of
the Installer Menu. Cooper Security hope that after you have followed these
detailed instructions then you will be familiar enough with the Installer Menu to
carry out any other programming task.
Addressing Keypads and Expanders on the Bus
30
50 160
When commissioning an alarm system the Installer will have made the control
unit give an address to all the devices connected to the bus at that time. If you
need to make subsequent changes to the system then please read the
following guidelines:
1.
When removing a device from the i-on EX bus always delete the device
from the Installer Menu first. This ensures that the deleted device has a
default bus address, and that all the other system information for that
device has been erased.
If you are removing a version 2 or version 3 i-kp01 from an i-on16 or i-
on40 you must manually default the address of the keypad before using it
on an i-onEX system.
2.
Always power down the system before connecting or disconnecting a
device from the bus.
3.
When adding a device to the bus make sure that it has a default bus
address first.
If you have a bus device taken from another system and you are not sure that
its address has been defaulted correctly, then:
To Manually Default The Bus Address Of An Expander
1. Disconnect the device from the bus (if you
have not already done so).
2. Open the lid (make sure that the tamper
switch operates).
3. Hold down the ―Request/Delete Address‖
button.
4. Apply 12Vdc power to the device (use the 0V
and 12V terminals on the bus connector).
After a few seconds the device sounder gives
the confirmation tone (two beeps) and the
display shows ―— -―.
5. Release the ―Request/Delete Address‖ button
after you hear the confirmation beeps.
Summary of Contents for i-On 40
Page 1: ......
Page 10: ...i on Range Page x This page is intentionally blank...