Installer Menu Options
i-on Range
Page 126
Speech Dialler
(For the i-on40, i-on30EX and i-on160EX this option appears only when the i-
sd02 or i-gsm02 module is fitted. For the i-on16 this option appears only when
the i-sd01 is fitted.)
The Test menu allows you to send a test speech call to any telephone number
(not just the ones programmed to receive speech messages in the event of an
alarm).
From the Installer Menu select
Test – Speech Dialler
.
The keypad display shows a message asking you to key in a telephone
number.
Key in the telephone number of the phone that you wish to receive the test
message and press
.
When you press
the control unit starts the test call. The keypad display
shows: ―Dialling...‖.
When the person at the receiving end answers the call the display shows
―Connected...‖.
The control unit will play the home message followed by each of the four alarm
messages, and then repeat all five messages three more times. While the
control unit is playing the messages the keypad display shows ―Playing
messages...‖.
The person receiving the messages call acknowledge (and end) the call by
pressing ―5‖ of ―9‖ on their phone keypad.
If no-one acknowledges a test call the keypad display shows ―No
acknowledgement‖.
PSU Current
30 40 50 160
The Test menu allows you to check how much current the control unit is
consuming. From the Installer menu select
Test – PSU Current
. The bottom line
of the keypad display shows the current delivered by the PSU in the control
unit.
Battery(s)
30 50 160
This option allows you to carry out a load test on any standby batteries
connected to the control unit, or of batteries in any EXP-PSU connected to the
system. From the Installer menu select
Test
–
Battery(s)
. The bottom line of
the keypad display shows the first in a list of all devices with standby batteries
connected (which is the control unit).
Press
or
to scroll up or down the list of devices.
Press
to start load testing the batteries connected to the device.
The keypad display shows the message ―Please wait...‖ while the device carries
out the load test. After several seconds the bottom line of the display shows