Installer Menu Options
i-on Range
Page 122
Zones
This option lets you select one or more individual zones,
and test only those zones and no others.
Use
u
or
n
to scroll up and down the list of zones. Press
or
to display ―Yes‖ at the end of the bottom line to
mark the zone as one you want to test.
When you select a Walk Test option (apart from the Chime option), the display
shows the first item in a list of the detectors available for test. Walk around the
area you wish to test and trigger each detector. If the Chime option is set to
―Yes‖ then every time you trigger a detector the keypads and loudspeakers
give confirmation tone. The bottom right of the display shows an ―A‖ if you
trigger the Alarm input and a ―T‖ if you trigger the Tamper.
The top of the display shows the number of zones left to test. The control unit
decreases the number of zones every time you trigger an individual Alarm
input.
The bottom line of the display shows the zone name. To see the zone number
press
or
.
Press
to end the test.
Note: Use the Walk Test option to test wired HUA switches. While you are
using the Walk Test option activating a wired HUA switch will not cause a
HUA alarm.
If you wish to see which zones have not yet been tested then press the menu
key. The bottom line of the display will show the first in a list of those zones
remaining to test. As you test each zone it will disappear from the display.
Press the menu key again to return to the full list of zones.
Testing Roller Shutter Detectors
160
EUR only.
When testing roller shutter detectors pull out the string so that the sensor
makes the required number of clicks within 20s.
Adjusting Roller Shutter Sensitivity
160
EUR only.
If you wish to change the sensitivity of roller shutter detectors then go to
Detectors/Devices – Detectors – Program Zones
, select the appropriate zone and
adjust the sensitivity figure. Remember to leave Installer Menu to save the
new figure before re-testing the zone.
Zone Resistances
30 40 50 160
When you select Zone Resistance, the display shows the first of the available
wired detectors. Press
or
to see the other detectors in the list.
The bottom line of the display shows the zone name. To see the zone number
press
or
.
The end of the bottom line shows the resistance of the zone. For 4-wire CC
zones the display alternates between the Alarm resistance (―A‖) and the
Tamper resistance (―T‖).