Chapter 9 Performance Test
9-20
11. Touch [PPG] at [Insert Error] once.
12. After measurement, confirm that the error count is 1.
13. Connect coaxial terminators to the PPG1 Data Out and ED1
Data In connectors. (Refer to (a) in Figure 9.2.2-2.)
14. Attach a 20 dB fixed attenuator to the PPG1 Data Out
connector.
15. Connect the PPG1 Data Out and Ch A In connectors using a
coaxial cable.
16. Repeat steps 5 to 7.
17. Connect the PPG1 Data Out and ED1 Data In connectors
using a coaxial cable. (Refer to (b) in Figure 9.2.2-2.)
18. On the [ED] tab, set Data Input Condition to [Single-Ended
XData].
19. Repeat steps 10 to 12.
ED2 can be tested in the same way with the Option 012.
The test connection diagram is the same as Figure 9.2.2-3.
ED3 and ED4 can be tested in the same way with the Option 014.